Analysis on Waterfall Tube Corrosion and Strength Calculation for Boilers Exceeding Service Life

Article Preview

Abstract:

Former USSR manufactured ΤΠ-230-2 type coal burning boiler has serviced for more than 369000 hours. The water fall tube burst caused by corrosion. The following examinations have been carried out , including macro-examination, metallographic analysis, tensile tests, inner and outer wall corrosion products and insulation materials analysis. Strength and remained thickness has also been calculated. Suggestions have been proposed to prevent similar explosions.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

695-698

Citation:

Online since:

February 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] General Administration of Quality Supervision Inspection and Quarantine of the P. R. China, Standardization Administration of the P.R. China. GB5310-2008Seamless steel tubes and pipes for high pressure boiler[s].

Google Scholar

[2] General Administration of Quality Supervision Inspection and Quarantine of the P.R. China, Standardization Administration of the P.R. China . GB 9222-2008 Strength calculation of pressure parts for watertube boiler[s].

Google Scholar