Study on Natural Ventilation Potential for Residential Buildings in Southern China

Article Preview

Abstract:

Existing methods for natural ventilation potential analysis are reviewed and discussed in this paper. Based on related research results, a simple natural ventilation potential prediction model for two-opening room is developed considering climatic conditions, local terrain conditions, building opening area and thermal comfort zone. In this model, several major cities in southern China are selected and the natural ventilation potential is analyzed by using the evaluation index of effective hours and effective air change rates. It shows that residential buildings in the south of China are suitable for natural ventilation generally, while effect differ significantly by region and season. The analysis results can help the designers to formulate the proper ventilation strategy and to make assessment of energy-saving effect.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 919-921)

Pages:

1610-1617

Citation:

Online since:

April 2014

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Germano M, Roulet C-A, Allard F, et al. Potential for natural ventilation in urban context: an assessment method. In: Proceedings of the 23rd conference of the air infiltration and ventilation centre, AIVC, Lyon, France, 2002. pp.519-25.

Google Scholar

[2] Fracastoro G V, Mutani G, Perino M.A simple tool to assess the feasibility of hybrid ventilation systems.In:Forth international conference on indoor air quality, ventilation and energy conservation in buildings—IAQVEC 2001, vol Ⅲ.Hongkong: The City of Hong Kong, 2001: 1421-29.

Google Scholar

[3] Yang L, Zhang G, Li Y, et al.Investigation potential of natural driving forces for ventilation in four major cities in China.Building and Environment.2005, 40: 738-46.

DOI: 10.1016/j.buildenv.2004.08.023

Google Scholar

[4] Zhiwen Luo, Jianing Zhao, Jun Gao, et al.Estimating natural-ventilation potential considering both thermal comfort and IAQ issues.Building and Environment.2007,42: 2289-98.

DOI: 10.1016/j.buildenv.2006.04.024

Google Scholar

[5] Liddament M W Air infiltration calculation techniques—an application guide, Air Infiltration and Ventilation Centre, International Network for Information on Ventilation, Brussels, Belgium.

Google Scholar

[6] Walker, I.S. and D.J. Wilson. 1994. Simple methods for improving estimates of natural ventilation rates. Proceedings of the 15th AIVC Conference, Buxton, U.K. September.

Google Scholar

[7] H B Awbi.Air movement in naturally-ventilated buildings.Renewable Energy, 1996, 8(2):241-47.

Google Scholar

[8] Walker, I.S. and Wilson, D.J. (1993) Evaluating models for superposition of wind and stack effect in air infiltration, Building and Environment , 28: 201-10.

DOI: 10.1016/0360-1323(93)90053-6

Google Scholar

[9] Richard J. de Dear, Gail S. Brager.Thermal comfort in naturally ventilated buildings:revisions to ASHRAE Standard 55.Energy and Buildings, 2002(34):549-61.

DOI: 10.1016/s0378-7788(02)00005-1

Google Scholar

[10] Su Xing, Zhang Xu, Gao Jun. Evaluation method of natural ventilation system based on thermal comfort in China. Energy and Buildings 2009; 41(1): 67–70.

DOI: 10.1016/j.enbuild.2008.07.010

Google Scholar