Abstract:

This research presents a numerical study of turbulent periodic flow and heat transfer in threedimensional isothermalfluxed square duct with diagonal inclined rib inserted. The fluid flow and heat transfer characteristics are presented for Reynolds numbers in the range of 4000 to 20,000. The computations based on the finite volume method, and the SIMPLE algorithm has been implemented. Effects of rib pitch ratios (0.5 to 2) at a single blockage ratio of 0.2 and attack angle of 60o on heat transfer and friction factor in the duct are examined and their results of the inclined rib are also compared with those of the smooth duct. It is found that the inclined rib provides higher heat transfer rate and friction factor than the smooth duct for all cases. In addition, the decreasing of the pitch ratio leads to the rise in the Nusselt number and friction factor.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 931-932)

Pages:

1144-1148

Citation:

Online since:

May 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Patankar S. V, Liu C.H. and Sparrow E.M. ASME J. Heat Transf. 1977; 99: 180-186.

Google Scholar

[2] Webb B.W. and Ramadhyani S. Int. J. Heat Mass Transf. 1985; 28: 1679–1687.

Google Scholar

[3] Kelkar K.M. and Patankar S.V. ASME J. Heat Transf. 1987; 109: 25–30.

Google Scholar

[4] Lopez J.R., Anand N.K. and Fletcher L.S. Numer. l Heat Transf. A: Appl. 1996; 30: 189–205.

Google Scholar

[5] Patankar S.V. Numerical heat transfer and fluid flow. McGraw-Hill. New York. (1980).

Google Scholar

[6] Incropera F. and Dewitt P. D, Introduction to heat transfer 5rd edition, John Wiley & Sons Inc. (2006).

Google Scholar