Indoor Environmental Quality (IEQ) Acceptance of Air Conditioned Buildings in Malaysia: Case Study of Universiti Tenaga Nasional

Article Preview

Abstract:

Indoor environmental quality (IEQ) is an important topic which impacts on energy efficiency and also productivity of occupants. Thermal comfort, indoor air quality, visual comfort and aural comfort are four main physical parameters which are normally used to determine IEQ. In this paper, the results of field study on IEQ conducted in the offices and student study areas of 6 air conditioned buildings in Universiti Tenaga Nasional in Malaysia are presented. The study was conducted during the month of October and November 2013, collecting a full set of objective physical measurements and subjective assessments through questionnaires. The measured environmental parameters are indoor air temperature, relative humidity, air velocity, carbon dioxide concentration, sound pressure level and luminance. The subjective responses concern the judgment of the respondents about the IEQ parameters at the moment of measurements. The results obtained showed that 86% of the respondents found that the IEQ is acceptable and the environmental conditions are mainly within the limits set by the various guidelines and standards in Malaysia. The neutral IEQ values were also determined through linear regression analysis of the sensation votes.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 953-954)

Pages:

1513-1519

Citation:

Online since:

June 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Ioan Sarbu, Calin Sebarchievici, Aspects of indoor environmental quality assessment in buildings', Department of Building Services, "Politehnica, University of Timisoara, Piata Bisericii 4A, 300233 Timisoara, Romania.

DOI: 10.56958/jesi.2021.6.4.4

Google Scholar

[2] Goldman R.F., Extrapolating ASHRAE's comfort model,. HVAC&R Research, 1999; 5(3): 189–94.

Google Scholar

[3] Mendell M.J. Indices for IEQ and building-related symptoms, Indoor Air, 2003; 13(4): 364–8.

DOI: 10.1046/j.0905-6947.2003.00229.x

Google Scholar

[4] Naganoa K., Horikoshib T. New comfort index during combined conditions of moderate low ambient temperature and traffic noise,. Energy and Buildings 2005; 37: 287–94.

DOI: 10.1016/j.enbuild.2004.08.001

Google Scholar

[5] Ibrahim Hussein, M. Hazrin A Rahman., Field study on thermal comfort in Malaysia, European Journal of Scientific Research, ISSN 1450-216X Vol. 37 No. 1 (2009), pp.134-152.

Google Scholar

[6] Lai A.C.K., Mui K.W., Wong L.T., An evaluation model for indoor environmental quality (IEQ) acceptance in residential buildings, . Energy and Buildings, 2009; 41: 930-6.

DOI: 10.1016/j.enbuild.2009.03.016

Google Scholar

[7] Fisk W.J., Health and productivity gains from better indoor environments and their relationship with building energy efficiency,. Annual Review of Energy and the Environment, 2000; 25: 537–66.

Google Scholar

[8] Jones A.P., Indoor air quality and health,. Atmospheric Environment, 1999; 33: 4535–64.

Google Scholar

[9] Wargocki P, Wyon D.P., Sundell J., Clausen G, Fanger P.O. The effects of outdoor air supply rate in an office on perceived air quality, Sick Building Syndrome (SBS) symptoms and productivity, Indoor Air, 2000; 10: 222–36.

DOI: 10.1034/j.1600-0668.2000.010004222.x

Google Scholar

[10] Design for acceptable indoor air quality, Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc; ANSI/ASHRAE Standard 62-(2007).

Google Scholar

[11] Mui K.W., Wong L.T., A method of assessing the acceptability of noise levels in air conditioned offices,. Building Services Engineering Research and Technology, 2006; 27(3): 249-54.

DOI: 10.1191/0143624406bse157tn

Google Scholar

[12] Li Huang, Yingxin Zhu, Qin Ouyang, Bin Cao., A study on the effects of thermal, luminous, and acoustic environments on indoor environmental comfort in offices,. Building and Environment 49 (2012) 304-309.

DOI: 10.1016/j.buildenv.2011.07.022

Google Scholar

[13] Clausen G, Wyon D.P., The combined effects of many different indoor environmental factors on acceptability and office work performance,. HVAC&R Research, 2008; 14(1): 103-13.

DOI: 10.1080/10789669.2008.10390996

Google Scholar

[14] Malaysian Meteorological Service, Annual Summary of Meteorological Observation, 1972-1997, Malaysian Meteorological Service, Kuala Lumpur, (1997).

Google Scholar

[15] L.T. Wong, K.W. Mui, P.S. Hui, A multivariate-logistic model of acceptance for indoor environment quality (IEQ) in offices, Building and Environment 43 (1) (2008) 1–6.

DOI: 10.1016/j.buildenv.2007.01.001

Google Scholar

[16] Portney L.G., Watkins M.P. Foundations of clinical research application to practice, 2nd edition. Upper Saddle River, N. J: Prentice-Hall Health; 2000, 07458.

Google Scholar

[17] Industry code of practice on Indoor Air Quality 2010, Department of Occupationally Safety and Health, Ministry of Human Resources, Malaysia JKKP DP(S) 127/379/4-39.

Google Scholar

[18] Malaysian Standard 1525 2007, Code of Practice on Energy Efficiency and Use of Renewable Energy for Non-Residential Buildings.

Google Scholar

[19] Environmental noise limits and control,. Department of Environment, Ministry of Natural Resources and Environment, Malaysia.

Google Scholar

[20] M. A Sulaiman, W.Z. Wan Yusoff, W.N. Wan Kamarudin. Evaluation of Indoor Environmental Quality (IEQ) on dense academic building: case studies Universiti Tun Hussein Onn Malaysia, International Journal of Scientific and Research Publications, Volume 3, Issue 1, January (2013).

DOI: 10.30880/ijie.2022.14.06.032

Google Scholar

[21] Yau Y.H., Chew. B.T. and Saifullah. A.Z.A. A Field Study on Thermal Comfort of Occupants and Acceptable Neutral Temperature at the National Museum in Malaysia,., Indoor and built environment, 2013; 22(2) 433-444.

DOI: 10.1177/1420326x11429976

Google Scholar

[22] K.W. Mui, L.T. Wong. Neutral temperature in subtropical climates-A field survey in air-conditioned offices, Building and Environment 42 (2007) 699–706.

DOI: 10.1016/j.buildenv.2005.10.021

Google Scholar

[23] J.F. Busch, Thermal responses to the Thai Office Environment, ASHRAE Transactions 96 (1), (1990).

Google Scholar

[24] R.J. De Dear, K.G. Leow, S.C. Foo, Thermal comfort in the humid tropics: Field experiments in air-conditioned and naturally ventilated buildings in Singapore, International Journal of Biometeorology 34, (1991).

DOI: 10.1007/bf01041840

Google Scholar