Study of the Effect of the Operating Conditions on the MCFC-Biomass Gasification Power Generation System

Article Preview

Abstract:

The combination of biomass gasification and molten carbonate fuel/micro-gas turbine (MCFC/MGT) hybrid system offers great potential as a future sustainable power generation system. A numerical model of a 100 kW classic MCFC/MGT hybrid system using biomass syngas as fuel has been developed. The simulation was performed to investigate the influence of operation conditions and the syngas compositions on the system performance. The results show that the MCFC/MGT can keep its performance when using syngas gas as fuel which confirms the feasibility of biomass gasification-MCFC/MGT hybrid system. According to the simulation results, the increase of MGT pressure ration and MCFC inlet temperature positively affects the system performance, the fluctuation of syngas composition has little effects on the system.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 953-954)

Pages:

317-320

Citation:

Online since:

June 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Nagel FP, Schildhauer TJ, McCaughey N. Biomass-integrated gasification fuel cell systems. Part 2. Economic analysis. Int J Hydrogen Energy 2009; 34: 6826-44.

DOI: 10.1016/j.ijhydene.2009.05.139

Google Scholar

[2] Wongchanapai S, Iwai H, Saito M. Performance evaluation of an integrated small-scale SOFC-biomass gasification power generation system[J]. J. Power Sources, 2012, 216: 314-322.

DOI: 10.1016/j.jpowsour.2012.05.098

Google Scholar

[3] Greppi P, Bosio B, Arato E. Feasibility of the integration of a molten carbonate fuel-cell system and an integrated gasification combined cycle. Int J. Hydrogen Energy, 2009, 34(20): 8664-8669.

DOI: 10.1016/j.ijhydene.2009.08.012

Google Scholar

[4] Y. Miyake, N. Nakanishi, T. Nakajima, A study of heat and material balances in an internalreformingmolten carbonate fuel cell, J. Power Sources 56 (1995) 11–17.

DOI: 10.1016/0378-7753(95)80002-x

Google Scholar

[5] F. Yoshiba, N. Ono, Y. Izaky, Numerical analyses of the internal condition of molten carbonate fuel cell stack: comparison of stack performances for various gas flow types, J. Power Sources 71 (1998)328–336.

DOI: 10.1016/s0378-7753(97)02727-4

Google Scholar

[6] B. Bosio, P. Costamagna, F. Parodi, Modeling and experimentation of molten carbonate fuel cell reactors in a scale-up process, Chem. Eng. Sci. 54 (1999) 2907–2916.

DOI: 10.1016/s0009-2509(98)00414-x

Google Scholar

[7] J. -H. Koh, B.S. Kang, H.C. Lim, Effects of various stack parameters on temperature rise in molten carbonate fuel cell stack operation, J. Power Sources 91 (2000) 161–171.

DOI: 10.1016/s0378-7753(00)00463-8

Google Scholar

[8] Donolo G, Simon G D, Fermeglia M. Steady state simulation of energy production from biomass by molten carbonate fuel cells. J. power sources, 2006, 158(2): 1282-1289.

DOI: 10.1016/j.jpowsour.2005.10.045

Google Scholar

[9] Aiguo Liu, Yiwu Weng. Modeling of Molten Carbonate Fuel Cell Based on the Volume-resistance Characteristics and Experimental Analysis. J. power sources, 195(2010): 1872-1879.

DOI: 10.1016/j.jpowsour.2009.10.040

Google Scholar

[10] Aiguo Liu, Yiwu Weng. Performance Analysis of Pressurized Molten Carbonate Fuel Cell/Micro Gas Turbine Hybrid System. J. power sources, 195 (2010): 204-213.

DOI: 10.1016/j.jpowsour.2009.07.024

Google Scholar