Study on Sub-Synchronous Control Interaction (SSCI) of Wind-Power Generator

Article Preview

Abstract:

Large-scale wind turbine generators with power electronic converters that operate near series compensated transmission lines are susceptible to un-damped sub-synchronous oscillations. This sub-synchronous oscillation is called Sub-synchronous Control Interaction (SSCI). With the rapid development of wind power technology, SSCI emerges as a new sub-synchronous oscillation phenomenon. The first SSCI event occurred for a wind farm in America in2009, which resulted in damage to the wind turbines. The origin of SSCI is presented and its characteristics of different types of wind turbines are summarized. Then the research prospect on this field is explored.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 953-954)

Pages:

518-521

Citation:

Online since:

June 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Sahni M, Muthumuni D, Badrzadeh B, et al. Transmission and Distribution Conference and Exposition (T&D), 2012 IEEE PES. IEEE, 2012: 1-9.

Google Scholar

[2] Garth Irwin. Subsynchronous Iteractions with Wind Turbines. Austin, (2010).

Google Scholar

[3] Irwin G D, Isaacs A, Woodford D. Transmission and Distribution Conference and Exposition (T&D), 2012 IEEE PES. IEEE, 2012: 1-4.

Google Scholar

[4] Gao Ben-feng, Zhao Cheng-yong, Xiao Xiang-ning,Guo Chun-lin,Zhao Yang. Transactions of China Electrotechnical Society, 2010, 11: 022.

Google Scholar

[5] Gao Ben-feng, Zhao Cheng-yong, Xiao Xiang-ning,Zhao Yang,Guo Chun-lin. Power System Protection and Control, 2010 (023): 6-10.

Google Scholar

[6] Li Wei, Xiao Xiangning, Zhao Yang. Transactions of China Electrotechnical Society, 2011, 26(4): 168-174.

Google Scholar

[7] BI Tian-shu, KONG Yong-le, XIAO Shi-wu, etal. Journal of Electric Power Science and Technology, 2012, 27(1): 10-15.

Google Scholar

[8] YAN Xiao-bin,LIU Tian-qi,LI Xing-yuan,TANG Fan. East China Electric Power, 2012, 40(8): 1328-1333.

Google Scholar

[9] G. Irwin, A.K. Jindal, A. L . Issacs. 2011 IEEE Power and Energy Society General Meeting, pp.1-6.

Google Scholar

[10] Wong W, Daniel J. ABB presentation on CREZ Reactive Study-ERCOT RPG Meeting[J]. (2010).

Google Scholar

[11] John Adams , Cathey Carter , Shun-Hsien (Fred) Huang. Transmission and Distribution Conference and Exposition (T&D), IEEE PES, (2012).

Google Scholar

[12] L.C. Gross, Sub-synchronous Grid Conditions: New Event, New Problem and New Solutions, 37th Annual Western Protective Relay Conference, Spokane, Washington, October 19th – 21st, (2010).

Google Scholar

[13] P. Belkin, Event of 10-22-09, CREZ Technical Conference, January 26, 2010, Electric Reliability Council of Texas.

Google Scholar

[14] Kidd D, Hassink P. Transmission and Distribution Conference and Exposition (T&D), 2012 IEEE PES. IEEE, 2012: 1-3.

Google Scholar

[15] Wang Ruilin. The Study of Torsional Vibration Between Wind Turbines and Grid[D]. Shanghai Jiao Tong University, (2012).

Google Scholar

[16] Badrzadeh B, Saylors S. Transmission and Distribution Conference and Exposition (T&D), 2012 IEEE PES. IEEE, 2012: 1-8.

Google Scholar