Thermal Properties of Silicon-Containing Polyimide Filled with Carbon Black of Low Structure

Article Preview

Abstract:

The nanocomposites between silicon-containing polyimide (SPI) and electrically conductive carbon black (CB) of low structure (Conductex K Ultra) were prepared. The contents of the conductive nanofillers were varied from 0 to 40 phr. The thermal properties of the nanocomposites were determined via Differential Scanning Calorimeter (DSC) and Thermo-gravimetric Analyzer (TGA). DSC thermograms revealed that the glass transition temperature (Tg) and degradation temperature (Td) of the nanocomposites increased with increasing the amount of fillers. The Tg and Td values of the composites filled with high structure were higher than those of the ones filled with low structure.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

21-24

Citation:

Online since:

June 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] S. Tiptipakorn, S. Damrongsakkul, S. Ando, K. Hemvichian, S. Rimdusit, Polym. Degrad. Stab. 92 (2007), 1265-1278.

DOI: 10.1016/j.polymdegradstab.2007.03.021

Google Scholar

[2] Information on http: /www. timcal. com/scopi/group/timcal/timcal. ns.

Google Scholar

[3] T. Kashiwagi, E. Grlke, J. Hilding, R. Harris, W. Awad, J. Douglas, Macromol. Rapid Comm. 23 (2002): 761-765.

DOI: 10.1002/1521-3927(20020901)23:13<761::aid-marc761>3.0.co;2-k

Google Scholar