Analysis on Coordination of Loss of Excitation Protection, Out-of-Step Protection and Out-of-Step Splitting

Article Preview

Abstract:

In units’ grid-related protection, loss of excitation protection and out-of-step protection are very important to ensure the stable running of grid. If both can realize the right coordination when unit occur a phenomenon of low excitation, it can improve the level of power source coordinated with grid. However, there is a problem in the coordination of both. Propose an idea to solve the problem based on power angle. Besides, out-of-step protection and out-of-step splitting exists a coordination relation according to the location of out-of-step oscillation center. In order to prevent the collapse of grid and protect units, it is necessary to cut off out-of-step lines and units correctly. Summarize the reasonable coordination relation between both by theory analysis and research.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 971-973)

Pages:

398-401

Citation:

Online since:

June 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] LIU Yi-dan, ZHANG xiao-yi, CUI Xiao-xiang. The Criterion probe of excitation protection impedance[J]. Power System Protection and Control, 2010, 38(20).

Google Scholar

[2] DL/T 1040-2007. Grid Run Standards[S]. Beijing: China Electric Power (2007).

Google Scholar

[3] Liu Qu. Power system stability and generator excitation control[M]. Beijing: China Electric Power Press, (2007).

Google Scholar

[4] LU Qiu-yu, XU Fei. New loss of excitation protection scheme based on coordinated optimization between generator and grid[J]. Power System Protection and Control,2013, 41(9):1-5.

Google Scholar

[5] GUO Chunping, Yu Zhen, Yin xiutao. The setting calculation of low excitation limit and loss protection[J]. China Electrical Engineering, 2012, 32(28): 129-132.

Google Scholar

[6] Liu Weiliang, Xun Jihui, Xue Wei. The setting coordination of loss protection and low excitation limit[J]. Automation of Electric Power Systems, 2008. 32(18).

Google Scholar

[7] Xu Jian, Xu jin, Wang Xiang. The Conflict and Coordination of Loss protection and out-of-step protection. Automation of Electric Power System, 2007, 31(17).

Google Scholar

[8] Wang Weijian. Main Electrical Equipment Relay Principles and Applications[M]. Beijing: China Electric Power Press, (2010).

Google Scholar