Hardware Implementation of Z-Source Inverter Based MPPT Scheme for Solar Power Conversion System

Article Preview

Abstract:

In this paper, the implementation of Z-Source Inverter based on Maximum power point tracking scheme (MPPT) for photovoltaic (PV) System is employed. This proposed work has the advantage of more power yield with reduced switching elements in power conditioner. Also a single stage power conversion circuit possessing Z-source network which replaces the boost converter set up in conventional mundane maximum power tracking circuits. The maximum power tracking is the trickiest part which is embedded within the inverter control. Therefore the control over inverter not only operates the PV panel at its maximum possible power but also have a check at the capacitor voltage of the Z-source network, thereby making the system more reliable and power efficient.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 984-985)

Pages:

819-827

Citation:

Online since:

July 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] H. Altas1, and A.M. Sharaf, A Photovoltaic Array Simulation Model for Matlab-Simulink GUI Environment, International conference on clean electric power 2007(ICCEP 07).

DOI: 10.1109/iccep.2007.384234

Google Scholar

[2] SavitaNema, R.K. Nema, GayatriAgnihotri, Matlab / simulink based study of photovoltaic cells / modules / array and their experimental verification, International Journal of Energy and Environment, Volume 1, Issue 3, 2010 pp.487-500.

Google Scholar

[3] De Brito, Galotto, Sampaio, De Azevedo e Melo, Canesin, Evaluation of the Main MPPT Techniques for Photovoltaic Applications,  IEEE Transactions on Industrial Electronics, Volume 60 , Issue 3, 2013 , 1156 – 1167.

DOI: 10.1109/tie.2012.2198036

Google Scholar

[4] Yinqing Zou, Youling Yu, Yu Zhang, Jicheng Lu, MPPT Control for PV Generation System Based on an Improved Inccond Algorithm, Procedia Engineering, Volume 29, 2012, Pages 105-109.

DOI: 10.1016/j.proeng.2011.12.677

Google Scholar

[5] N.  Femia, G. Petrone, G. Spagnuolon, and M. Vitelli, Optimization of Perturb and observe maximum power point tracking method, IEEE Transactions on Power Electronics, vol. 20, no. 4, p.963–973, Jul. (2005).

DOI: 10.1109/tpel.2005.850975

Google Scholar

[6] L. Fangrui, D. Shanxu, L. Fei, L. Bangyin, and K. Yong, A variable step size INC MPPT method for PV systems, IEEE Trans. Ind. Electron., vol. 55, no. 7, pp.2622-2628, Jul (2008).

DOI: 10.1109/tie.2008.920550

Google Scholar

[7] F.Z. Peng, Z-source inverter, IEEE Transactions on Industry Applications, vol. 39, pp.504-510, (2003).

Google Scholar

[8] F.Z. Peng, S. Miaosen, Q. Zhaoming, Maximum boost control of the Z-source inverter, IEEE Transactions in Power Electronics, vol. 20, pp.833-838, (2005).

DOI: 10.1109/tpel.2005.850927

Google Scholar

[9] F. Z. Peng, A. Joseph, J. Wang, M. Shen, L. Chen, Z. Pan, E. Ortiz-Rivera, and Y. Huang, Z-source inverter for motor drives, IEEE Transactions in Power Electronics, vol. 20, no. 4, p.857–863, Jul. (2005).

DOI: 10.1109/tpel.2005.850938

Google Scholar

[10] P.C. Loh, D. M. Vilathgamuwa, Y. S. Lai, C. Geok Tin, Y. Li, Pulse width modulation of Z-source inverters, IEEE Transactions in Power Electronics, vol. 20, pp.1346-1355, (2005).

DOI: 10.1109/tpel.2005.857543

Google Scholar

[11] S. Miaosen, W. Jin, A. Joseph, F.Z. Peng, L.M. Tolbert, D.J. Adams, Constant boost control of the Z-source inverter to minimize current ripple and voltage stress, IEEE Transactions in Industry Applications, vol. 40, pp.770-778, (2006).

DOI: 10.1109/tia.2006.872927

Google Scholar

[12] SengodanThangaprakash, Unified MPPT Control Strategy for Z-Source Inverter Based Photovoltaic Power Conversion, 2012, published in journal of power electronics.

DOI: 10.6113/jpe.2012.12.1.172

Google Scholar

[13] J. W. Jung and A. Keyhani, Control of a fuel cell based Z-source Converter, IEEE Transactions in Energy Conversion, Vol. 22, No. 2, pp.467-476, Jun. (2007).

DOI: 10.1109/tec.2006.874232

Google Scholar

[14] V. Arun, B. Shanthi, Performance Evaluation of Multicarrier SPWM Strategies for Three Phase Z - source Seven Level Diode Clamped Inverter, International Journal of Engineering Trends and Technology (IJETT) – Vol. 4, Issue 6, June (2013).

DOI: 10.1007/978-81-322-1035-1_13

Google Scholar

[15] S. Mohamed Yousuf, P. Vijayadeepan, Dr.S. Latha, Analysis of Multi-Carrier PWM Control Techniques for Neutral Clamped Multilevel Z-Source Inverter, International Conference on Computing and Control Engineering (ICCCE 2012), 12 & 13 April, (2012).

Google Scholar

[16] M. Shen, A. Joseph, J. Wang, F. Z. Peng, and D. J. Adams, Comparison of traditional inverters and Z-source inverter for fuel cell vehicles, IEEE Transaction in Power Electronics, Vol. 22, No. 4, pp.1453-1463, Jul. (2007).

DOI: 10.1109/tpel.2007.900505

Google Scholar

[17] F. Z. Peng, M. Shen and K. Holland, Application of Z-Source Inverter for Traction Drive of Fuel Cell Battery Hybrid Electric Vehicles, IEEE Transactions in Power Electronics, vol. 22, no. 3, pp.1054-1061, (2007).

DOI: 10.1109/tpel.2007.897123

Google Scholar