Abstract:

On the basis of establishing direct geo-positioning model for three-line array sensor ADS40/80 images, in order to optimize the positioning accuracy, the self-calibration technology was used to update the ADS40/80 sensor imaging parameters. Moreover, the ADS40/80 camera error model and self-calibration bundle adjustment model were set up. Multi-groups of ADS40 data over the Songshan experimental field were used for direct geo-positioning and parameter updating experiments. Experimental results proved that the self-calibration adjustment technique can effectively update sensor imaging parameters and significantly improve image direct positioning accuracy.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 989-994)

Pages:

3534-3539

Citation:

Online since:

July 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Li Deren. GPS for Photogrammetry and Remote Sensing, Beijin: Surveying and Mapping Press(1996).

Google Scholar

[2] M. Cramer, Digital Airborne Cameras – Status and Future, Proceedings ISPRS Workshop High Resolution Earth Imaging for Geospatial Information, University of Hannover, Hannover/Germany, May 17-20(2005).

Google Scholar

[3] L. Hinsken. S. Miller. U. Tempelmann. R. Uebbing. Triangulation of LH Systems' ADS40 imagery using ORIMA GPS/IMU. International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences, (2002), 34 (Part 3A): 156–162.

Google Scholar

[4] Sandual, Design Principles of the LH Systems ADS40 Airborne Digital Sensor. Int . Arch. of Photogrammetry and Remote Sensing, (2000), Vol. 33 Part B2: 258-265.

Google Scholar

[5] WANG Zhizhuo. PhotoGrammetry Principle. Wuhan: Wuhan University Press(2007).

Google Scholar

[6] WANG Tao, Study on Theories and Methods of Linear CCD Sensor Geometric Calibration Based on Field , Zhengzhou: Information Engineering University Doctor Thesis(2012).

Google Scholar

[7] Brown, D.C. The Bundle Adjustment – Process and Prospects. Invited paper, Commission III, Proc. of XIIIth ISP Congress, Helsinki, Finland, International Archives of Photogrammetry 21(3), p.33(1976).

Google Scholar

[8] TU Xinru, XU Miaozhong, LIU Li. The Geometric Calibration of Airborne Three-line-scanner ADS40. Acta Geodaetica et Cartographica Sinica, 2011, 40(1): 78-83.

Google Scholar