Field Investigations, Simulation and Numerical Analysis of the Suitability of Aluminium Opening Design in the Residential Sector Inmauritius

Article Preview

Abstract:

The use of aluminium as material of choice in the manufacture of window and door openings in Mauritius has escalated significantly in recent years. This has given rise to a considerable number of small-and medium-sized companies operating in the aluminium fabrication sector. The main aim of this study was to identify and investigate the common problems reported with aluminium openings and to assess the structural resistance, water-tightness and safety of the openings. A survey was carried out among local aluminium importers and fabrication companies to gather information about the different profiles and grades of aluminium commonly used for exterior window and door applications in the residential sector. A questionnaire was designed and circulated to clients of aluminium fenestration products. This helped to identify the most common problems encountered with aluminium openings. Site visits were also conducted which enabled the investigation of some common problems identified such as water ingress and rigidity of moving parts. The structural loading of openings was assessed using finite element analysis using SolidWorks. Models of openings of different sizes and corresponding to typical opening designs used locally were created and a uniform pressure was applied on the frames. This uniform pressure was derived from a wind speed of 280 km/h – the maximum wind speed used for design calculations for buildings in Mauritius. The resulting deflections were analysed and compared to the maximum permissible deflections – which were calculated using the guidelines of North American Fenestration Standard (NAFS-11). Results showed that the maximum deflections for frames sizes exceeding a span of 1.5 m, exceeded the maximum allowable values, and necessitated the use of more rigid profiles. Deflections observed in the triple frame design were also higher than those in the double frame. These observations point out to the need of selecting the right profiles for different sized applications to ensure that openings do not incur significant deflections when subjected to wind loads, which would be encountered during severe cyclonic conditions in the island.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

3-13

Citation:

Online since:

August 2022

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2022 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] The International Aluminium Institute, Statistics, [Online]. Available at: https://www.world-aluminium.org/statistics/. Accessed in August (2021).

Google Scholar

[2] David Appelfeld, Christian S. Hansen, Svend Svendsen, Development of a slim window frame made of glass fibre reinforced polyester, Energy and Buildings. 42.10 (2010)1918 – (1925).

DOI: 10.1016/j.enbuild.2010.05.028

Google Scholar

[3] Australian Window Association (2016), A Guide To Window and Door Selection, [Online]. Available at https://www.agwa.com.au/resources/selection-guide. Accessed in August (2021).

Google Scholar

[4] C.T. Salzano, F.J. Masters, J.D. Katsaros, Water penetration resistance of residential window installation options for hurricane-prone area, Building and Environment. 45.6 (2010) 1373–1388.

DOI: 10.1016/j.buildenv.2009.12.002

Google Scholar

[5] Nathan Van Den Bossche, Arnold Janssens, Airtightness and watertightness of window frames: Comparison of performance and requirements, Building and Environment. 110 (2016)129-139.

DOI: 10.1016/j.buildenv.2016.09.034

Google Scholar

[6] Carlos Lopez, Forrest J. Masters, Scott Bolton, Water penetration resistance of residential window and wall systems subjected to steady and unsteady wind loading, Building and Environment. 46 (2011) 1329 – 1342.

DOI: 10.1016/j.buildenv.2010.12.008

Google Scholar

[7] B. Gerlach, W. Fricke, Experimental and numerical investigation of the behavior of ship windows subjected to quasi-static pressure loads, Marine Structures. 46 (2016) 255-272.

DOI: 10.1016/j.marstruc.2016.02.001

Google Scholar

[8] Rogiros Illampas, Dimos C. Charmpis, Ioannis Ioannou, Laboratory testing and finite element simulation of the structural response of an adobe masonry building under horizontal loading, Engineering Structures. 80 (2014) 362-376.

DOI: 10.1016/j.engstruct.2014.09.008

Google Scholar

[9] Mark G. Stewart, Paraic C. Ryan, David J. Henderson, John D. Ginger, Fragility analysis of roof damage to industrial buildings subject to extreme wind loading in non-cyclonic regions, Engineering Structures, 128 (2016) 333–343.

DOI: 10.1016/j.engstruct.2016.09.053

Google Scholar

[10] http://chicagowindowexpert.com/2009/04/22/types-of-window-leaks-glazing-leaks/. Accessed in August (2021).

Google Scholar