Assessing Indoor Air Quality Indices and Airborne Contaminant Exposure in Isolation Rooms with Protected Zone Ventilation Systems: A Comprehensive Review

Article Preview

Abstract:

Airborne transmission of pathogens, particularly through respiratory droplets and aerosols, poses a significant risk to human health and contributes to the spread of infectious respiratory disorders. Urbanization and population increase are frequently linked to rising energy consumption and the use of natural resources like fossil fuels, which harms the ecology. Solar and geothermal energy are examples of renewable energy sources that provide options that can help with environmentally friendly and cost-effective energy-efficient thermal comfort solutions. Adequate ventilation plays a crucial role in mitigating this risk and safeguarding human well-being. Previous studies have examined the importance of ventilation in airborne infection control, emphasizing its impact on indoor air quality. This paper aims to comprehensively review various control measures for enhancing indoor air quality, taking into account relevant influencing parameters. Additionally, the study explores sustainable solutions that can contribute to the long-term prevention of declining air quality and mitigate the potential impact of future biological threats on human health. A thorough literature study evaluates the performance of protected zone ventilation in reducing the risk associated with respiratory droplets and aerosols generated by infected individuals in different confined spaces. The findings highlight the significance of guideline recommendations to prevent airborne transmission of infections and offer a concise overview of enhanced ventilation strategies for improving indoor air quality, particularly in air-conditioned environments. The results of this review contribute to a deeper understanding of the effectiveness of protected zone ventilation in reducing the spread of respiratory pathogens. Moreover, they provide insights into the importance of maintaining optimal indoor air quality through appropriate ventilation measures. The implications of this research are crucial for developing evidence-based guidelines and strategies that can mitigate the impact of airborne transmission and foster healthier indoor environments.

You might also be interested in these eBooks

Info:

Pages:

85-96

Citation:

Online since:

June 2024

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2024 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] "World Health Organization. WHO Global Air Quality Guidelines: Particulate Matter (PM2.5 and PM10), Ozone, Nitrogen Dioxide, Sulfur Dioxide and Carbon Monoxide, electronic version; World Health Organization: Geneva, Switzerland, 2021; ISBN 9789240034228".

Google Scholar

[2] "World Health Organization. Combined or Multiple Exposure to Health Stressors in Indoor Built Environments: An Evidence-BasedReview Prepared for the WHO Training Workshop 'Multiple Environmental Exposures and Risks': 16–18 October 2013, Bonn, Germany;World Health Organization, Regional Office for Europe: Copenhagen, Denmark, 2013.".

Google Scholar

[3] ˙I.; Tekin, Ö.F.; Erbas, O. Arikan, "Arikan, ˙I.; Tekin, Ö.F.; Erbas, O. Relationship between sick building syndrome and indoor air quality among hospital staff. Med. Lav. 2018, 109, 435–443. [CrossRef] [PubMed]".

Google Scholar

[4] P. Lasomsri, P. Yanbuaban, O. Kerdpoca, and T. Ouypornkochagorn, "A Development of Low-Cost Devices for Monitoring Indoor Air Quality in a Large-Scale Hospital."

DOI: 10.1109/ecticon.2018.8619934

Google Scholar

[5] P. Rautiainen, M. Hyttinen, J. Ruokolainen, P. Saarinen, J. Timonen, and P. Pasanen, "Indoor air-related symptoms and volatile organic compounds in materials and air in the hospital environment," Int J Environ Health Res, vol. 29, no. 5, p.479–488, Sep. 2019.

DOI: 10.1080/09603123.2018.1550194

Google Scholar

[6] A. J. Cohen et al., "Estimates and 25-year trends of the global burden of disease attributable to ambient air pollution: an analysis of data from the Global Burden of Diseases Study 2015," The Lancet, vol. 389, no. 10082, p.1907–1918, May 2017.

DOI: 10.1016/S0140-6736(17)30505-6

Google Scholar

[7] Y. Liu et al., "Aerodynamic analysis of SARS-CoV-2 in two Wuhan hospitals," Nature, vol. 582, no. 7813, p.557–560, Jun. 2020.

DOI: 10.1038/s41586-020-2271-3

Google Scholar

[8] J. W. Tang et al., "Dismantling myths on the airborne transmission of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2)," Journal of Hospital Infection, vol. 110. W.B. Saunders Ltd, p.89–96, Apr. 01, 2021.

DOI: 10.1016/j.jhin.2020.12.022

Google Scholar

[9] A. Aganovic and G. Cao, "Evaluation of airborne contaminant exposure in a single-bed isolation ward equipped with a protected occupied zone ventilation system," Indoor and Built Environment, vol. 28, no. 8, p.1092–1103, Oct. 2019.

DOI: 10.1177/1420326X18823048

Google Scholar

[10] H. H. Al-Kayiem, K. Koh, T. W. B. Riyadi, and M. Effendy, "A comparative review on greenery ecosystems and their impacts on sustainability of building environment," Sustainability (Switzerland), vol. 12, no. 20. MDPI, p.1–26, Oct. 02, 2020.

DOI: 10.3390/su12208529

Google Scholar

[11] F. Yuan et al., "Thermal comfort in hospital buildings – A literature review," Journal of Building Engineering, vol. 45. Elsevier Ltd, Jan. 01, 2022.

DOI: 10.1016/j.jobe.2021.103463

Google Scholar

[12] H. A. Saheb, A. A. Mahdi, and Q. R. Al-amir, "A Comparative Study of Performance Between Two Combined Ventilation Systems and Their Effect On Indoor Air Quality and Thermal Comfort Inside Office Rooms," IOP Conf Ser Mater Sci Eng, vol. 1095, no. 1, p.012001, Feb. 2021.

DOI: 10.1088/1757-899x/1095/1/012001

Google Scholar

[13] M. Hajdukiewicz, M. Geron, and M. M. Keane, "Calibrated CFD simulation to evaluate thermal comfort in a highly-glazed naturally ventilated room," Build Environ, vol. 70, p.73–89, Dec. 2013.

DOI: 10.1016/j.buildenv.2013.08.020

Google Scholar

[14] W. Mareed and H. Hussen, "Numerical and Experimental Modeling of Indoor Air Quality Inside a Conditioned Space with Mechanical Ventilation and DX-Air Conditioner," Engineering and Technology Journal, vol. 38, no. 9, p.1257–1275, Sep. 2020.

DOI: 10.30684/etj.v38i9a.875

Google Scholar

[15] E. Rivas, J. L. Santiago, F. Martín, and A. Martilli, "Impact of natural ventilation on exposure to SARS-CoV 2 in indoor/semi-indoor terraces using CO2 concentrations as a proxy," Journal of Building Engineering, vol. 46, Apr. 2022.

DOI: 10.1016/j.jobe.2021.103725

Google Scholar

[16] L. Morawska et al., "How can airborne transmission of COVID-19 indoors be minimised?," Environment International, vol. 142. Elsevier Ltd, Sep. 01, 2020.

DOI: 10.1016/j.envint.2020.105832

Google Scholar

[17] N. Agarwal et al., "Indoor air quality improvement in COVID-19 pandemic: Review," Sustain Cities Soc, vol. 70, Jul. 2021.

DOI: 10.1016/j.scs.2021.102942

Google Scholar

[18] R. K. Bhagat, M. S. Davies Wykes, S. B. Dalziel, and P. F. Linden, "Effects of ventilation on the indoor spread of COVID-19," J Fluid Mech, vol. 903, 2020.

DOI: 10.1017/jfm.2020.720

Google Scholar

[19] J. Ding, C. W. Yu, and S. J. Cao, "HVAC systems for environmental control to minimize the COVID-19 infection," Indoor and Built Environment, vol. 29, no. 9, p.1195–1201, Nov. 2020.

DOI: 10.1177/1420326X20951968

Google Scholar

[20] A. Fadaei, "Ventilation Systems and COVID-19 Spread: Evidence from a Systematic Review Study," European Journal of Sustainable Development Research, vol. 5, no. 2, p. em0157, Apr. 2021.

DOI: 10.21601/ejosdr/10845

Google Scholar

[21] N. Agarwal et al., "Indoor air quality improvement in COVID-19 pandemic: Review," Sustain Cities Soc, vol. 70, Jul. 2021.

DOI: 10.1016/j.scs.2021.102942

Google Scholar

[22] M. Hyttinen et al., "Airborne infection isolation rooms - A review of experimental studies," Indoor and Built Environment, vol. 20, no. 6. p.584–594, Dec. 2011.

DOI: 10.1177/1420326X11409452

Google Scholar

[23] M. Hyttinen et al., "Airborne infection isolation rooms - A review of experimental studies," Indoor and Built Environment, vol. 20, no. 6. p.584–594, Dec. 2011.

DOI: 10.1177/1420326X11409452

Google Scholar

[24] N. Ma, D. Aviv, H. Guo, and W. W. Braham, "Measuring the right factors: A review of variables and models for thermal comfort and indoor air quality," Renewable and Sustainable Energy Reviews, vol. 135. Elsevier Ltd, Jan. 01, 2021.

DOI: 10.1016/j.rser.2020.110436

Google Scholar

[25] A. Fonseca, I. Abreu, M. J. Guerreiro, and N. Barros, "Indoor Air Quality in Healthcare Units—A Systematic Literature Review Focusing Recent Research," Sustainability (Switzerland), vol. 14, no. 2. MDPI, Jan. 01, 2022.

DOI: 10.3390/su14020967

Google Scholar

[26] G. Cao et al., "A review of the performance of different ventilation and airflow distribution systems in buildings," Building and Environment, vol. 73. p.171–186, Mar. 2014.

DOI: 10.1016/j.buildenv.2013.12.009

Google Scholar

[27] J. L. Santarpia et al., "Aerosol and Surface Transmission Potential of SARS-CoV-2".

DOI: 10.1101/2020.03.23.20039446

Google Scholar

[28] D. G. Karottki et al., "An indoor air filtration study in homes of elderly: cardiovascular and respiratory effects of exposure to particulate matter," 2013. [Online]. Available: http://www.ehjournal.net/content/12/1/116

Google Scholar

[29] H. C. Chuang, L. Y. Lin, Y. W. Hsu, C. M. Ma, and K. J. Chuang, "In-car particles and cardiovascular health: An air conditioning-based intervention study," Science of the Total Environment, vol. 452–453, p.309–313, May 2013.

DOI: 10.1016/j.scitotenv.2013.02.097

Google Scholar

[30] F. A. Berlanga, M. R. de Adana, I. Olmedo, J. M. Villafruela, J. F. San José, and F. Castro, "Experimental evaluation of thermal comfort, ventilation performance indices and exposure to airborne contaminant in an airborne infection isolation room equipped with a displacement air distribution system," Energy Build, vol. 158, p.209–221, Jan. 2018.

DOI: 10.1016/j.enbuild.2017.09.100

Google Scholar

[31] D. Al Assaad, K. Ghali, and N. Ghaddar, "Effectiveness of intermittent personalized ventilation assisting a chilled ceiling for enhanced thermal comfort and acceptable indoor air quality," Build Environ, vol. 144, p.9–22, Oct. 2018.

DOI: 10.1016/j.buildenv.2018.08.005

Google Scholar

[32] S. Liu, G. Cao, B. E. Boor, and A. Novoselac, "A Protected Occupied Zone Ventilation System to Prevent the Transmission of Coughed Particles."

Google Scholar

[33] Z. Cheng, A. Aganovic, G. Cao, and Z. Bu, "Experimental and simulated evaluations of airborne contaminant exposure in a room with a modified localized laminar airflow system," Environmental Science and Pollution Research, vol. 28, no. 24, p.30642–30663, Jun. 2021.

DOI: 10.1007/s11356-021-12685-4

Google Scholar

[34] S. Zhang, D. Niu, Y. Lu, and Z. Lin, "Contaminant removal and contaminant dispersion of air distribution for overall and local airborne infection risk controls," Science of The Total Environment, vol. 833, p.155173, Aug. 2022.

DOI: 10.1016/j.scitotenv.2022.155173

Google Scholar

[35] S. ALJABAIR, I. ALESBE, and A. ALKHALAF, "CFD modeling of influenza virus diffusion during coughing and breathing in a ventilated room," Journal of Thermal Engineering, p.127–137, Jan. 2023.

DOI: 10.18186/thermal.1243491

Google Scholar

[36] J. Cho, "Investigation on the contaminant distribution with improved ventilation system in hospital isolation rooms: Effect of supply and exhaust air diffuser configurations," Appl Therm Eng, vol. 148, p.208–218, Feb. 2019.

DOI: 10.1016/j.applthermaleng.2018.11.023

Google Scholar

[37] F. F. Al-ajmi, D. L. Loveday, K. H. Bedwell, and G. Havenith, "Thermal insulation and clothing area factors of typical Arabian Gulf clothing ensembles for males and females: Measurements using thermal manikins," Appl Ergon, vol. 39, no. 3, p.407–414, 2008.

DOI: 10.1016/j.apergo.2007.10.001

Google Scholar

[38] N. Agarwal et al., "Indoor air quality improvement in COVID-19 pandemic: Review," Sustain Cities Soc, vol. 70, Jul. 2021.

DOI: 10.1016/j.scs.2021.102942

Google Scholar

[39] M. Saeed, A. Al, K. Supervised, A. Ali, and N. Alashaab, "NUMERICAL INVESTIGATION ON THERMAL COMFORT IN A MOSQUE IN BAGHDAD-IRAQ."

Google Scholar

[40] K. H. Dunn, T. Mckernan, and A. Garcia, "Engineering Controls, Work Practices, and Exposure Monitoring for Occupational Exposures to Diacetyl and 2,3-Pentanedione." [Online]. Available: www.cdc.gov/niosh.

DOI: 10.26616/nioshpub2015197

Google Scholar

[41] J. O. Anderson, J. G. Thundiyil, and A. Stolbach, "Clearing the Air: A Review of the Effects of Particulate Matter Air Pollution on Human Health," Journal of Medical Toxicology, vol. 8, no. 2. p.166–175, Jun. 2012.

DOI: 10.1007/s13181-011-0203-1

Google Scholar

[42] N. Canha et al., "Assessment of ventilation and indoor air pollutants in nursery and elementary schools in France," Indoor Air, vol. 26, no. 3, p.350–365, Jun. 2016.

DOI: 10.1111/ina.12222

Google Scholar

[43] P. M. Bluyssen, "European indoor air quality audit project in 56 office buildings," Indoor Air, vol. 6, no. 4, p.221–238, 1996.

DOI: 10.1111/j.1600-0668.1996.00002.x

Google Scholar

[44] C. Vornanen-Winqvist et al., "Ventilation positive pressure intervention effect on indoor air quality in a school building with moisture problems," Int J Environ Res Public Health, vol. 15, no. 2, Feb. 2018.

DOI: 10.3390/ijerph15020230

Google Scholar

[45] A. M. Elsaid and M. S. Ahmed, "Indoor Air Quality Strategies for Air-Conditioning and Ventilation Systems with the Spread of the Global Coronavirus (COVID-19) Epidemic: Improvements and Recommendations," Environmental Research, vol. 199. Academic Press Inc., Aug. 01, 2021.

DOI: 10.1016/j.envres.2021.111314

Google Scholar

[46] B. Friberg, M. Lindgren, C. Karlsson, A. Bergström, and S. Friberg, "Mobile zoned/exponential LAF screen: A new concept in ultra-clean air technology for additional operating room ventilation," Journal of Hospital Infection, vol. 50, no. 4, p.286–292, Apr. 2002.

DOI: 10.1053/jhin.2001.1164

Google Scholar

[47] Y. Zhang et al., "Adaptive Wall-Based Attachment Ventilation: A Comparative Study on Its Effectiveness in Airborne Infection Isolation Rooms with Negative Pressure," Engineering, vol. 8, p.130–137, Jan. 2022.

DOI: 10.1016/j.eng.2020.10.020

Google Scholar

[48] E. Ding, D. Zhang, and P. M. Bluyssen, "Ventilation regimes of school classrooms against airborne transmission of infectious respiratory droplets: A review," Building and Environment, vol. 207. Elsevier Ltd, Jan. 01, 2022.

DOI: 10.1016/j.buildenv.2021.108484

Google Scholar

[49] S. Ferrari, T. Blázquez, R. Cardelli, G. Puglisi, R. Suárez, and L. Mazzarella, "Ventilation strategies to reduce airborne transmission of viruses in classrooms: A systematic review of scientific literature," Building and Environment, vol. 222. Elsevier Ltd, Aug. 15, 2022.

DOI: 10.1016/j.buildenv.2022.109366

Google Scholar

[50] M. Gola, G. Settimo, and S. Capolongo, "Indoor Air Quality in Inpatient Environments: A Systematic Review on Factors that Influence Chemical Pollution in Inpatient Wards," Journal of Healthcare Engineering, vol. 2019. Hindawi Limited, 2019.

DOI: 10.1155/2019/8358306

Google Scholar

[51] I. Eames, J. W. Tang, Y. Li, and P. Wilson, "Airborne transmission of disease in hospitals," Journal of the Royal Society Interface, vol. 6, no. SUPPL. 6. Royal Society, Dec. 06, 2009.

DOI: 10.1098/rsif.2009.0407.focus

Google Scholar

[52] X. Y. Ge et al., "Evaluation of the exposure risk of SARS-CoV-2 in different hospital environment," Sustain Cities Soc, vol. 61, Oct. 2020.

DOI: 10.1016/j.scs.2020.102413

Google Scholar

[53] T. Jin et al., "SARS-CoV-2 presented in the air of an intensive care unit (ICU)," Sustain Cities Soc, vol. 65, Feb. 2021.

DOI: 10.1016/j.scs.2020.102446

Google Scholar