Stub Setting Fixture Prototype on High Voltage Overhead Transmission Line Tower Installation

Article Preview

Abstract:

High voltage overhead transmission line is a transmission tower used to conduct electricity with a voltage of 35 kV to 230 kV. In the installation of the HV overhead transmission line tower structure, one of the main things that need to be considered is the installation of stub that can affect the sturdiness of the tower. This research aims to design and make a stub setting fixture on the HV overhead transmission tower installation. The research process began with data observation and literature study of tower stub installation in the 150kV 2xZebra Andolo – Kasipute Sec.1 installation project of PT. PLN Persero UIP South Sulawesi, then designed the stub setting fixture components, design data analysis, and fixture manufacturing. The results of the analysis of the design structure experienced do not exceed the limits of the material stresses of the component, the analysis of machine elements in the stub setting fixture is able to withstand the loads experienced by the component. It is expected that there will be improvements and development of fixture in the form of more efficient forms of construction and operation, and can use analog and digital controls in terms of fixture operation in subsequent development and research.

You might also be interested in these eBooks

Info:

Periodical:

Engineering Headway (Volume 20)

Pages:

103-114

Citation:

Online since:

March 2025

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2025 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] D. Fink and H. Beaty, Standard Handbook For Electrical Engineers, 15th ed. New York: McGraw-Hill Professional, 2006.

Google Scholar

[2] X. Fu, H. N. Li, and G. Li, "Fragility analysis and estimation of collapse status for transmission tower subjected to wind and rain loads," Structural Safety, vol. 58, p.1–10, Jan. 2016.

DOI: 10.1016/J.STRUSAFE.2015.08.002

Google Scholar

[3] X. Fu, H. Li, and JX Li, "Wind-resistance and failure analyses of a lightning-damaged transmission tower," ascelibrary.org, vol. 32, no. 1, p.04017127, Feb. 2018.

DOI: 10.1061/(ASCE)CF.1943-5509.0001121

Google Scholar

[4] F. Kiessling, P. Nefzger, J. F. Nolasco, and U. Kaintzyk, "Overhead Power Lines," 2003.

DOI: 10.1007/978-3-642-97879-1

Google Scholar

[5] PT. PLN (Persero), Maintenance Manual Book of High Voltage and Extra High Voltage Overhead Transmission Line. Jakarta: PT. PLN (PERSERO), 2014.

DOI: 10.15676/ijeei.2021.13.3.6

Google Scholar

[6] E. Hoffman, Jig and fixture design, 5th ed. New York: Delmar, Cengage Learning, 2004.

Google Scholar

[7] P. H. Joshi, Jig and Fixture Design Manual, 2nd ed. New York: McGraw-Hill Professional, 2003.

Google Scholar

[8] R. D. Bhosale, S. S. Nalawade, P. Swami, P. Gaikwad, and R. R. Patil, "Study & design of jig and fixture for base frame of canopy fabrication of generator," academia.edu, 2017.

Google Scholar

[9] PT. Danusari Mitra Sejahtera, "Tower 150 kV SUTT 2XZebra Setting Stub Manufacturing drawing doc. no.: DMS-150KV-AA6-15." Bogor, 2019.

Google Scholar

[10] R. S. Khurmi and J. K. Gupta, A Text Book of Machine design. New Delhi: S. Chand Publishing, 2005.

Google Scholar

[11] R. G. Budynas and J. K. Nisbett, Shigley's Mechanical Engineering Design, 8th ed. New York: McGraw-Hill Companies, 2008.

Google Scholar

[12] American Society for Testing and Materials, ASTM A283: Standard Specification for Low and Intermediate Tensile Strength Carbon Steel Plates. 2013.

Google Scholar

[13] American Society for Testing and Materials, ASTM F 1145: Standard Specification for Turnbuckles, Swaged, Welded, Forged. West Conshohocken: American Society for Testing and Materials, (2001)

DOI: 10.1520/f1145

Google Scholar