Steam Power Plant’s Loads and Efficiency of the Subcritical Pulverized Coal Boiler: A Case in Kendari City

Article Preview

Abstract:

Steam Power Plant (PLTU) is a type of thermal power plants widely used nowadays due to its high in efficiency. PLTU Moramo is an Independent Power Producer (IPP) that supplies electricity to PT PLN and has two generating units which produce 2 x 50 MW of electricity. The main goal of this research is to investigate effect of the steam power plant’s electricity loads on efficiency of the Subcritical Pulverized Coal (PC) Boiler and to determine values of the boiler’s efficiency based on the three vary loading capacity which are 30 MW net, 40 MW net, and 50 MW net respectively. Method applying to calculate the boiler efficiency in this research is an indirect method or heat loss method of calculation based on the heat loss value for each parameter, then the boiler efficiency is determined. Results obtained in this research showed that by using indirect method or the heat loss method, thermal efficiency of the boiler decreases as the boiler’s loading capacity is increased. Based on this research, thermal efficiency of the boiler is 81.15 % for the loading capacity of 30 MW net and decreasing to 80.20 % and 79.20 % for 40 MW net load and 50 MW net load respectively

You might also be interested in these eBooks

Info:

Periodical:

Engineering Headway (Volume 20)

Pages:

61-68

Citation:

Online since:

March 2025

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2025 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Hidayat, Sudarsono, R. Othman, Dynamic behavior of human tympanic membrane preforation using finite element metho, IOP Conference Series: Materials Science and Engineering, Volume 797 (2020) 1-5

DOI: 10.1088/1757-899x/797/1/012025

Google Scholar

[2] R.R. Sisworo, M. Hasegawa, K. Nakashima, Y. Norimatsu, Y. Tada, Generation of Monodispersed Spherical Thermosensitive Gels and Their Swelling and Shrinking Behaviours in Aqueous Polymeric Solutions, Applied Sciences.10.6 (2020) 1-17

DOI: 10.3390/app10062016

Google Scholar

[3] K. Zhang, Z. Liu, Y. Wang, Y. Li, Q. Li, J. Zhang, H. Liu, Flash evaporation and thermal vapour compression aided energy saving CO2 capture systems in coal-fired power plant, Energy, Vol 66, 2014, pp.556-568.

DOI: 10.1016/j.energy.2014.01.063

Google Scholar

[4] F. Kreith, D.Y. Goswami, The CRC Handbook of Mechanical Engineering 2nd Ed, CRC Press, Washington D.C, (2015)

Google Scholar

[5] Amiya, Practical Boiler Operation Engineering and Power Plant, PHI learning private limited, Delhi, 2014.

Google Scholar

[6] SMEPTC4, Fired Steam Generators, New York, 2013.

Google Scholar

[7] Dongfang, Instruction For 2x50MW Boilers of Indonesia Kendari Coal Fired Power Plant Project, Dongfang Boiler Co Ltd, Indonesia, 2016.

Google Scholar

[8] C.G. Corporation, Fired Steam Generator Performance Test Procedure. Kendari: PT MECHATRON Teknologi Industri, Indonesia, 2016.

Google Scholar

[9] V. Ganapathy, Steam Generators and Waste Heat Boilers, New York, 2015.

Google Scholar

[10] Y. Men, X. Liu, T. Zhang, A Review of Boiler Waste Heat Recovery Technologies in the Medium Low-Temperature Range, Vol 237, 2021.

DOI: 10.1016/j.energy.2021.121560