An Experimental Study on the Shear Behavior of Perforated Shear Connector with Flange Head

Article Preview

Abstract:

Concrete-steel composite members are formed by bonding a steel component, such as an I-section beam, to a concrete component, such as a reinforced concrete slab, so that the two components can act as a unit. The use of such type of composite member becomes main stream of construction technology since it provides efficient load resisting mechanism in structural system. In a composite member, bond between steel and concrete is a crucial factor for the composite action. Usually this bond behavior is achieved by installation of mechanical device so called shear connector. The composite action can be divided into two categories (i.e., full and partial) depending on the shear strength of mechanical shear connector embedded in the concrete, i.e., understanding of shear load resisting mechanism is necessary to develop a new shear connector for better, wider and more efficient application of composite action. For this purpose, the push-out tests are performed for the evaluation of several existing shear connectors including carefully designed perforated shear connector with flange head. One of the purposes of this experimental research is to define the shear resisting mechanism of the proposed new type shear connector. The experimental results show that the degree of composite action using perforated shear connector with flange head is superior to those of existing shear connectors such as a general headed stud, perfobond, etc. The experimental parameters, such as the number of perforated holes, the distance between perforated holes, and the height of shear connector, are carefully chosen for the verification of their effect on the capacity of shear resistance. From this experimental investigation it was found that the mechanical performance of proposed shear connector was efficient as a rigid shear connector.

You might also be interested in these eBooks

Info:

Periodical:

Key Engineering Materials (Volumes 306-308)

Pages:

1349-1354

Citation:

Online since:

March 2006

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2006 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] E.C. Oguejiofor and M.U. Hosain: Proc. Intl. Conf. on Steel and Aluminum Structures, Volume on Composite Steel Structures, Singapore, (May 1991), p.62.

Google Scholar

[2] CEN prEN 1994: Eurocode 4 Final Draft (Brussels 2002).

Google Scholar

[3] E.C. Oguejiofor: Ph. D. Thesis (University of Saskatchewan, Saskatoon 1994).

Google Scholar

[4] D.J. Oehlers and G. Sved: National Conference Publication-Institution of Engineers Vol. 2 No. 8 (1994), p.619.

Google Scholar