Efficacy of HA Block Kyphoplasty for Old Osteoporotic Spine Fractures

Article Preview

Abstract:

We have successfully treated osteoporotic spine fractures for about three years, by using transpedicular kyphoplasty with hydroxyapatite blocks (HA Block: PENTAX) (refer with: Fig. 1), The 13 patients, four men and nine women, ranged from 61 to 86 years in age (mean, 73 years). The mean Visual Analogue Scale (VAS) was 8.5 points before operation, improved to 2.7 points on the next day of operation, and improved significantly to 1.8 points at the final evaluation. The mean deformity rate (Anterior height / Posterior height x 100) was 66.3% before operation, but improved to 91.7% immediately after operation. At the time of follow-up, this rate was 78.6%, indicating that the correction loss was 13.1%. This procedure caused none of serious complications such as neurological disorder and pulmonary infarction. Kyphoplasty with HA blocks may be safe and effective in the treatment of chronic vertebral fractures.

You might also be interested in these eBooks

Info:

Periodical:

Key Engineering Materials (Volumes 309-311)

Pages:

1371-1374

Citation:

Online since:

May 2006

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2006 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] P. Galibert , H. Deramond ,P. Rosat , D and Le Gars: Note preliminaire sur le traitement des angimes vertebraux par vertebroplastie acrylique percutanee. Neurochirurgie. Vol. 33 , (1987), 166-168.

Google Scholar

[2] M. E. Jensen, A. J. Evans, J. M. Mathis, D. F. Kallmes, H. J. Cloft and J. E. Dion: Percutaneous Polymethylmethacrylate Vertebroplasty in the Treatment of Osteoprotic Vertebral Body Compression Fractures: Technical Aspect. Am J Neuroradiol. Vol. 18 (1997).

Google Scholar

[3] S.R. Garfin, H.A. Yuan and M.A. Reiley: New technologies in spine: kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures. Spine. 2001, Vol 26 (14): 1511-5.

DOI: 10.1097/00007632-200107150-00002

Google Scholar

[4] S.M. Belkoff, J.M. Mathis, E.M. Erbe and D.C. Fenton: Biomechanical evaluation of a new bone cement for use in vertebroplasty. Spine. 2000, Vol 25 (9): 1061-4.

DOI: 10.1097/00007632-200005010-00004

Google Scholar

[5] K.Y. Yoo, S.W. Jeong, W. Yoon and J. Lee: Acute respiratory distress syndrome associated with pulmonary cement embolism following percutaneus vertebroplasty with polymethylmethacrylate. Spine. Vol. 29 (2004), 294-297.

DOI: 10.1097/01.brs.0000131211.87594.b0

Google Scholar