Stress Analysis of the Human Skull due to the Insertion of Rapid Palatal Expander with Finite Element Analysis (FEA)

Article Preview

Abstract:

The study aims at analyzing the stress state of the human skull with FEA, simulating the loads due to the insertion of rapid palatal expanders with two or four arms. A 3D CAD solid model of a human skull has been created starting from CT slices. Using FEA, forces that simulate the loads developed by the expander have been applied to the solid model of the skull to determine the stress state.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

211-218

Citation:

Online since:

October 2008

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2009 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Information on http: /en. wikipedia. org.

Google Scholar

[2] Galantucci, L.M., Percoco, G., Angelelli, G., Lopez, C., Introna, F., Liuzzi, C., De Donno, A., Reverse engineering techniques applied to a human skull, for CAD 3D reconstruction and physical replication by rapid prototyping, Journal of Medical Engineering and Technology, Volume 30, Issue 2, March 2006, pp.102-111.

DOI: 10.1080/03091900500131714

Google Scholar

[3] Eropkin, S.V., Potapov, A.A., Kravchuk, A.D., Kornienko, V.N., Belova, T.V., Panchenko, V.I., Evseev, A.V. Perspective of skull reparative surgery using three-dimensional computed tomography and stereolithography [Perspektivy rekonstruktivnoi khirurgii cherepa s ispol'zovaniem trekhmernoi komp'iuternoi tomografii i stereolitografii. ] Zhurnal Voprosy Nejrokhirurgii Imeni N.N. Burdenko, 2002, pp.53-55.

Google Scholar

[4] Bill, J.S., Reuther, J.F., Dittmann, W., Kübler, N., Meier, J.L., Pistner, H., Wittenberg, G. Stereolithography in oral and maxillofacial operation planning. International Journal of Oral and Maxillofacial Surgery, 24, 1995, pp.98-103.

DOI: 10.1016/s0901-5027(05)80869-0

Google Scholar

[5] Pham, D.T., Gault, R.S. A comparison of rapid prototyping technologies International Journal of Machine Tools and Manufacture, 38 (10-11), 1998, pp.1257-1287.

DOI: 10.1016/s0890-6955(97)00137-5

Google Scholar

[6] Morcovescu, V., Drăgulescu, D., Reconstruction of the Human Femur Based on CT Slices to Perform the Finite Element Analysis, in The Scientific Bulletin of 'Politehnica', University from Timisoara, Mechanics series, (2002).

Google Scholar

[1] [2] [3] [4] [5] [6] [7] [8] [9] 0 0, 1 0, 2 0, 3 0, 4 0, 5 0, 6 0, 7 0, 8 0, 9 1 Parametric distance [-] Von Mises Stress [MPa] Figure 15. The distribution of the the Von Mises stress along the base line of the palatal suture.

Google Scholar