The Effects of Opening Windows Behavior on Indoor Air Quality of a Newly Decorated Office Building

Article Preview

Abstract:

In the newly decorated office premises, the architectural decoration material will release much polluted gas, thus the IAQ is highly concerned. Natural ventilation through open windows can influence the IAQ. To study the effects of opening windows on the indoor air quality of newly decorated office premises, we choose several newly decorated offices in a commercial building in Changsha, a city in hot summer and cold winter region of China, as the study object. The 4 contrastive research schemes in the winter are adopted to acquire the results. Field-testing and air sampling methods were taken respectively to the 4 schemes to measure the concentrations of the main pollution composition such as formaldehyde, ammonia, benzene and TVOC in the offices. Meanwhile, relevant questionnaire surveys towards the four schemes were taken to the staff in the offices. We have synthesized and analyzed the IAQ condition of the 4 research schemes from the results of the tests and surveys. The result of the study shows that: the IAQ is the worst and cannot come up to the national standard when closing windows all day long in the newly decorated offices. Also some staff have a series of adverse reactions working in the work environment for a long time. All the other three schemes can improve the IAQ differently, and the scheme that opening windows all day long can improve the IAQ the best. Meanwhile, people can feel the change of IAQ effected by the 3 ventilation schemes if he/she is working for a long time in the offices.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

892-896

Citation:

Online since:

June 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Sun L. and An Y. 2005. Effects of newly decorated and air conditioned office on the health of people. Chinese journal of Clinical Rehabilitation, January 21, 2005 Vol. 9 No. 3.

Google Scholar

[2] R Menzies. et al. 1991. The effect of varying levels of outdoor ventilation on symptoms of sick building syndrome. IAQ'91 Healthy Buildings, (1991).

Google Scholar

[3] Lv L. and Kang B. 2002. Objective and Subjective Evaluations on Indoor Air Quality of Offices. Chinese Journal of Public Health Engineering 2002. No. 1. Vol. 1.

Google Scholar

[4] GB/T1883-2002. Indoor Air Quality Standard. 2002; 9~10.

Google Scholar

[5] Shen J. et al. 1996. Subjective Evaluations on Indoor Air Quality of Office Buildings in Shanghai. Building Energy & Environment. 1996, 15(2); 8~13.

Google Scholar

[6] ASHRAE Standard, 62-2001. Ventilation for acceptable indoor air quality. (2001).

Google Scholar

[7] WHO. 1990. Report on a World Health Organization, Indoor Environment Health Aspects of Air Quality. Thermal Environment Light and Noise. (1990).

Google Scholar