[1]
S. Russo, F. Sciarretta, Masonry exposed to high temperatures: Mechanical behaviour and properties — An overview, Fire Saf. J. 55 (2012) 69-86.
DOI: 10.1016/j.firesaf.2012.10.001
Google Scholar
[2]
Th. -D. Nguyen, F. Meftah, R. Chammas, A. Mebarki, The behaviour of masonry walls subjected to fire: modelling and parametric studies in the case of hollow burnt-clay bricks, Fire Saf. J. 44 (2009) 629-641.
DOI: 10.1016/j.firesaf.2008.12.006
Google Scholar
[3]
F. R. R. Ayala, Mechanical properties and structural behaviour of masonry at elevated temperatures, PhD Thesis, University of Manchester, (2010).
Google Scholar
[4]
M. Andreini, M. Sassu, Mechanical behaviour of full unit masonry panels under fire action, Fire Saf. J. 46 (2011) 440-450.
DOI: 10.1016/j.firesaf.2011.07.004
Google Scholar
[5]
G. Boscato, A. Dal Cin, S. Russo, F. Sciarretta, SHM of Historic Damaged Churches. Adv. Mat. Res. 838-841 (2014) 2071-(2078).
DOI: 10.4028/www.scientific.net/amr.838-841.2071
Google Scholar
[6]
G. Boscato, A. Dal Cin, F. Sciarretta, E. Sperotto, S. Russo, Structural health monitoring of basilica plan churches damaged by earthquake, in: Proc. Int. Conf. on Engineering and Applied Sciences - ICEAS, Beijing, 24-27th July 2012, China.
Google Scholar
[7]
G. Boscato, D. Rocchi, S. Russo, F. Sciarretta, M. Pizzolato, Modelling procedure for structural characterization of monumental buildings, in: Proc. 14th Int. Conf. on Computing in Civil and Building Engineering (ICCCBE), Moscow, June 27-29, (2012).
Google Scholar
[8]
G. Boscato, S. Russo, F. Sciarretta, The double-layered façades of Palazzo Ducale in Venice: results from testing and long-term monitoring, in: Proc. 8th Int. Conf. on Structural Analysis of Historical Constructions - SAHC 2012, Wroclaw 15-17th Oct. (2012).
Google Scholar
[9]
G. Boscato, G. Riva, S. Russo, F. Sciarretta, ND tests for a first assessment of mechanical behaviour of the stone-covered façades of Palazzo Ducale in Venice, in: Proc. 12th Int. Conf. on Structural Repairs and Maintenance of Heritage Architecture, 5-7 Sept. 2011 Chianciano, Italy.
DOI: 10.2495/str110511
Google Scholar
[10]
G. Boscato, S. Russo, F. Sciarretta, Structural Monitoring of the Slender Double-Layered Façade of Palazzo Ducale in Venice - Preliminary Analysis of Measurements, Mas. Int., 24 (2011) 57-72.
Google Scholar
[11]
S. Russo, G. Boscato, F. Sciarretta, Behaviour of a Historical Masonry Structure Subjected to Fire, Mas. Int., 21 (2008) 1-14.
Google Scholar
[12]
ASTM E119-95a – Standard test methods for fire tests of building construction and materials, American Society for Testing and Materials (1995).
Google Scholar
[13]
Eurocode 1: Actions on structures: actions in case of fire, UNI EN 1991-1-2 (2005).
Google Scholar
[14]
S. Russo, F. Sciarretta, Experimental and theoretical investigation on masonry after high temperature exposure, Exp. Mech. 52 (2012) 341-359.
DOI: 10.1007/s11340-011-9493-0
Google Scholar
[15]
S. Russo, F. Sciarretta, Residual strength of traditional brick masonry subjected to high temperatures, in: Proc. 1st Conference on Protection of Historical Buildings – ProHiTech 09, Rome 21-24 June (2009).
Google Scholar
[16]
F. Sciarretta, Modelling of mechanical damage in traditional brickwork walls after fire exposure, Advanced Materials Research 919-921 (2014) 495-499.
DOI: 10.4028/www.scientific.net/amr.919-921.495
Google Scholar