A Parametric Study on Exterior Insulation Systems and Heat Reflective Paints for Energy Efficiency in Buildings

Article Preview

Abstract:

Buildings are responsible for at least 40% of the used energy in most of the countries and the figure is rising as the construction booms. But pace of energy saving in building is much lower in India as compared to developed countries. So, there is an immediate need to open up new techniques to address the issue and also progress in the area of actual implementation should be accelerated immediately because both knowledge and techniques are available today to slash the energy usage in a building.Our focus is mainly on the modification of building envelope to reduce the energy used for cooling in A/C building and to reduce the temperature of the interior of non-A/C building.Berger has developed different systems such as EIFS for wall, Roof insulation and Heat reflecting paint for both wall & roof. The efficiency of these systems in terms of energy saving and cooling has been tested at Howrah and also has been tested by CBRI at Roorkee, through actual field study for two years. The test results revealed that the maximum energy saving of 32.33% can be achieved for A/C building. For non A/C building, maximum temperature difference of 6.4°C between outdoor and indoor air of the room can be achieved.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

71-81

Citation:

Online since:

July 2015

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Zielnik, A. Hot topic, concepts: Energy-efficiency mandate continues to drive technology advances in coatings, building envelope systems , Durability + Design, the Journal of architectural coating, Vol 1, No 4, July/August- 2011, Page 36-47.

Google Scholar

[2] Zubielewicz, M. Making keeping cool easier, European Coatings Journal, 01/2012, Page 24-29.

Google Scholar

[3] Brenk,B., Helsel J.L., Restoration role powers the sustainability prowess of reflective roof coatings, Durability + Design, the Journal of architectural coating, Vol 2, No 2, March/April 2012, Page 36-40.

Google Scholar

[4] Scarborough, W., Roof coatings study builds knowledge base on performance questions, Durability + Design, the Journal of architectural coating, Vol 1, No 6, Nov/Dec- 2011, Page 22-28.

Google Scholar

[5] Raskin, R., Innovations in thermal reflective and barrier coatings, Polymer Paint Colour Journal, Vol 201, No 4563, August 2011, Page 31-32.

Google Scholar

[6] Energy Conservation Building Code User Guide V-0. 2, 2009(Reprinted 2011).

Google Scholar

[7] Zeng, X., Zhu, D., Review of Building Energy Saving Techniques, Proceedings of the Sixth International Conference for Enhanced Building Operations, Shenzhen, China, Nov 6-9, (2006).

Google Scholar

[8] Guide Line for European Technical Approval of External Thermal Insulation. Composite Systems with Rendering , ETAG 004 Edition March (2000).

Google Scholar

[9] Guide To Exterior Insulation & Finish System Construction , EIMA Issue 6/07.

Google Scholar

[10] Technical Manual No. IB/01/2001, Bolix EIFS Technology Insulation Systems.

Google Scholar

[11] IGBC Green Homes Rating System Ver 1. 0, April (2009).

Google Scholar