Application of Numerical Method and Statistical Analysis in the Integrated Intensity Calculation of the Peaks from the X-Ray Diffraction (XRD) Pattern of α-Iron

Article Preview

Abstract:

The aim of this work is to analyze the error of the calculated integrated intensity of the x-ray peaks of a-iron (BCC-Fe) powder from x-ray diffraction (XRD) pattern by using the numerical method and the statistical analysis. The a-Fe powder was characterized by the x-ray diffractometer using step scan mode, step sizes 0.03o 2q and 0.05o 2q, and preset times from 0.1 to 3.5 s. The integrated intensity () of an x-ray peak and its error () were calculated using numerical method. The correlation between the relative error () and the preset time or step size were analyzed by the statistical analysis methods which are linear regression and statistical hypothesis testing. The results from the statistical analysis at significance level of 0.05 show that the relative error () correlate with x = preset time or integrated intensity by when a1 and a2 are the positive constants. From the mathematical model, for this work, the step size does not affect the relative error. However, the increasing of preset time reduces relative error on integrated intensity calculation. To minimize the error on XRD analysis, the preset time should be greater than one second. Moreover, on a XRD pattern, the lower integrated intensity peak has the higher relative error.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

350-354

Citation:

Online since:

August 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] H. Wang, Step Size, Scanning Speed and Shape of X-ray Diffraction Peak, J. Appl. Cryst. 27 (1994) 716-721.

DOI: 10.1107/s002188989400186x

Google Scholar

[2] A.J.C. Wilson, Statistical Variance of Line-Profile Parameters. Measures of Intensity, Location and Dispersion, ActaCryst. 23 (1967) 888-898.

DOI: 10.1107/s0365110x67003998

Google Scholar

[3] B.D. Culity and S.R. Stock, Elements of X-Ray Diffraction, third ed., Prentice Hall, New Jersey, (2001).

Google Scholar

[4] R.L. Burden and J.D. Faires, Numerical Analysis, ninth ed., Cengage Learning, (2010).

Google Scholar

[5] P. Chakartnarodom and N. Chuankrerkkul, Statistical Analysis of Binder Behavior during Debinding Step in Powder Injection Molding (PIM), Adv. Mat. Res. 970 (2014) 172-176.

DOI: 10.4028/www.scientific.net/amr.970.172

Google Scholar

[6] H.D. Young, Statistical Treatment of Experimental Data, McGraw-Hill, (1962).

Google Scholar

[7] R.E. Walpole, R.H. Myers, Probability and Statistics for Engineers and Scientists, fifth ed., Prentice-Hall Inc., New Jersey, (1993).

Google Scholar

[8] E. Laitila, Design and Set-up of XRD Experiments, XRDUG Session 1, Michigan Technological University, (2007).

Google Scholar