Carbon Fiber Strips Retrofitting System for Precast Reinforced Concrete Wall Panel

Article Preview

Abstract:

This paper presents the retrofitting procedure used on a precast reinforced concrete wall panel (PRCWP) in order to restore its initial load bearing capacity. The specimen used in this experimental test is one from the residential multistoried buildings constructed in Romania from the 1970 onwards. All of the characteristics of the element are from the specific era, only scaled down with a factor of 1:1,2. The element was subjected to in-plane reversed cyclic loading to simulate its seismic behavior and obtain its maximum load bearing capacity. After the test we retrofitted the element using Carbon Fiber Strips Externally Bonded (EBR) and anchored with Carbon Fiber Reinforced Polymers (CFRP) mesh. The porpoise of the paper is to compare the maximum loading bearing capacity of the unstrengthen and strengthen elements in order to compare them and examine the efficiency of this retrofitting procedure.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

208-212

Citation:

Online since:

August 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] I. Demeter, Seismic retrofit of precast RC walls by externally bonded CFRP composites. Romania: PhD Thesis, Politehnica University of Timisoara, (2011).

Google Scholar

[2] B. Mohammed, L.W. Ean, M.A. Malek, One way RC wall panels with openings strengthened with CFRP, Construction and Building Materials, 40 (2013) 575-583.

DOI: 10.1016/j.conbuildmat.2012.11.080

Google Scholar

[3] B. Li, K. Qian, Retrofitting earthquake-damaged RC structural walls with openings by externally bonded FRP strips and sheets, Journal of Composites for Constructions, 17 (2013) 259–270.

DOI: 10.1061/(asce)cc.1943-5614.0000336

Google Scholar

[4] T. El Maaddawy, S. Sherif, FRP composites for shear strengthening of reinforced concrete deep beams with openings, Composite Structures, 89 (2009) 60-69.

DOI: 10.1016/j.compstruct.2008.06.022

Google Scholar

[5] O. Enochsson, J. Lundqvist, B. Taljsten, P. Rusinowski, T. Olofsson, CFRP strengthened openings in two-way concrete slabs - an experimental and numerical study, Construction and Building Materials, 21 (2007) 810-826.

DOI: 10.1016/j.conbuildmat.2006.06.009

Google Scholar

[6] S.C. Florut, G. Sas, C. Popescu, V. Stoian, Tests on reinforced concrete slabs with cut-out openings strengthened with fibre-reinforced polymers, Composites Part B: Engineering, 66 (2014) 484-493.

DOI: 10.1016/j.compositesb.2014.06.008

Google Scholar