Pedestrian Wind Comfort around the Reinforced-Concrete Atypical Structure

Article Preview

Abstract:

The high-rise buildings in built-up areas affect the surrounding pedestrian-level wind environment. Unpleasant gust strong wind especially between the buildings, on corners, the crossing points and passages, will experience these locations as not comfortable or dangerous. The series of parametric wind tunnel studies were carried out to investigate the effects of building width, height and the gap width between buildings on the pedestrian-level wind environment. In the article, we will discuss build up area around designed reinforced concrete structure with atypical shape - TWIN CITY A1 Bratislava (developer company: HB Reavis). We indicated the high wind speed areas for discomfort under strong wind conditions experimentally in BLWT wind tunnel and using CFD simulation. It is important to note that the wind effects applied on the reinforced-concrete structures and occurring around these structures are one of the most important input parameters in their design. Therefore, they should not be neglected. As it was mentioned above, this paper deals only with the wind effects occurring around the examined structure. The wind effects applied on the structure – determination of the external wind pressure coefficients, were discussed in [1].

You might also be interested in these eBooks

Info:

Periodical:

Pages:

153-163

Citation:

Online since:

June 2017

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2017 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] O. Hubova, L. Konecna, Experimental Determination of Wind Flowing around a Building Configuration, Procedia Engineering. 161 (2016) 1845-1851. ScienceDirect ISSN 1877-7058.

DOI: 10.1016/j.proeng.2016.08.701

Google Scholar

[2] G. B. Wiren, A wind tunnel study of wind velocities in passages between and through buildings, in: Proceedings of the 4th International Conference on Wind Effects on Buildings and Structures, Heathrow, (1975).

Google Scholar

[3] T. Stathopoulos, R. Storms, Wind environmental condition in passages between buildings, Journal of Wind Engineering and Industrial Aerodynamics. 24 (1) (1986) 19-31.

DOI: 10.1016/0167-6105(86)90070-x

Google Scholar

[4] T. Stathopoulos, H. Wu, C. Bedant, Wind environment around buildings: a knowledge –based approach, Journal of Wind Engineering and Industrial Aerodynamics. 41-44 (1992) 2377-2388.

DOI: 10.1016/0167-6105(92)90028-9

Google Scholar

[5] T. Stathopoulos, Haqing Wu, Generic models for pedestrian – level winds in built – up region, Journal of Wind Engineering and Industrial Aerodynamics, 54-55 (1995) 515-525.

DOI: 10.1016/0167-6105(94)00068-o

Google Scholar

[6] B. Blocken, T. Stathopoulos, J. Carmeliet, Wind Environmental Conditions in Passages between Two Long Narrow Perpendicular Buildings, Journal of Aerospace Engineering. (2008) 280-287. 10. 1061/(ASCE)0893-1321(2008)21: 4(280).

DOI: 10.1061/(asce)0893-1321(2008)21:4(280)

Google Scholar

[7] C.W. Tsang, K.C.S. Kwok, P.A. Hitchcock, Effects of building dimensions and separations on pedestrian – level environment, in: 5th European & African Conference on Wind Engineering, Florence, Italy, July 19-23, (2009).

Google Scholar

[8] Tsang, C., Kwork, K., Hitchcock (2012).

Google Scholar

[9] EN 1991-1-4: Eurocode 1: Action on structures – Part 1-4: General actions-Wind actions, (2005).

Google Scholar

[10] E. Willemsen, A.J. Wisse, Design for wind comfort in The Netherlands: Procedures, criteria and open research issues, Journal of Wind Engineering and Industrial Aerodynamics. 95(9-11) (2007) 1541 – 1550.

DOI: 10.1016/j.jweia.2007.02.006

Google Scholar

[11] A.G. Davenport, An Approach to Human Comfort Criteria for Environmental Wind Conditions. CIBA/WMO Colloquium Teaching the Teachers, Swedish National Building Research Institute, Stockholm, (1972).

Google Scholar

[12] M. Vido for SIEBER + TALAS. LTD, Technical report – TWIN CITY A1 Bratislava (HB Reavis), (2016).

Google Scholar

[13] D. Zacho, O. Hubova, P. Lobotka, Simulating the natural wind in BLWT – wind tunnel in Laboratories of STU, in: New Trends in Statics and Dynamics of Buildings, 11th International Conference, Bratislava, Slovakia, 2013, pp.259-262.

Google Scholar

[14] B. Blocken, J. Carmeliet, Pedestrian Wind Environment around Builings: Literature Reviw and Practival Examples, Journal of Thermal Envelope and Building Science, 28 (2) (2004), 107-159.

DOI: 10.1177/1097196304044396

Google Scholar

[15] ANSYS Inc., ANSYS Fluent User's Guide, Release 17. 2, (2016).

Google Scholar

[16] J. Franke, A. Hellsten, H. Schlunzen, B. Carissimo, Best practice guideline for the CFD simulation of flows in the urban environment, COST Office Brussels, (2007).

DOI: 10.1504/ijep.2011.038443

Google Scholar

[17] Y. Tominaga, A. Mochida, R. Yoshie, H. Kataoka, T. Nozu, M. Yoshikawa, T. Shirasawa, AIJ guidelines for practical applications of CFD to pedestrian wind environment around buildings, Journal of Wind Engineering and Industrial Aerodynamics. 96 (10-11) (2008).

DOI: 10.1016/j.jweia.2008.02.058

Google Scholar

[18] T.H. Shih, W.W. Liou, A. Shabbir, J. Zhu, A new k-e eddy-viscosity model for high Reynolds number turbulent flows - model development and validation, Computers and Fluids. 24(3) (1995) 227–238.

DOI: 10.1016/0045-7930(94)00032-t

Google Scholar

[19] J. Franke, C. Hirsch, A.G. Jensen, H.W. Krus, M. Schatzmann, P.S. Westbury, S.D. Miles, J.A. Wisse, N.G. Wright, Recommendations on the use of CFD in wind engineering, in: van Beeck, J.P.A.J. (Eds. ), Proceedings of the International Conference on Urban Wind Engineering and Building Aerodynamics. COST Action C14, Impact of Wind and Storm on City Life Built Environment. Von Karman Institute, Sint-Genesius-Rode, Belgium, 5–7 May, (2004).

DOI: 10.5359/jawe.35.63

Google Scholar