Experimental Study on the Corrosion Behavior of Produced Fluid on J55 Steel during CO2 Flooding

Article Preview

Abstract:

CO2 flooding has been widely used in oil field development, but the produced fluid is easy to cause corrosion of tubing and casing. In order to determine the corrosion behavior of produced fluid on J55 steel during CO2 flooding, we use the simulated oil well produced fluid as corrosive medium and conduct the corrosion simulation experiment at high temperature and high pressure. The experimental results showed that the crystalline grain size of corrosion film surface is different for the different CO2 partial pressure. When CO2 partial pressure is greater than the critical pressure, the crystalline grain is not oblique six-party crystal structure, and the grains become small and compact, so the corrosion product film should have a good corrosion inhibition. Both static and dynamic corrosion of samples are serious. The research has a theoretical guiding significance on corrosion protection during CO2 flooding.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

179-183

Citation:

Online since:

July 2018

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2018 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Z. H. Zhang, J. B. Guo. Law of CO2 Corrosion of Oil Country Tubular Goods and the Study of Its Progress at Home and Abroad. Bao Steel Tech. 4 (2000) 54-58.

Google Scholar

[2] J. Zheng. Carbon dioxide corrosion mechanism. Fault-block Oil & Gas Field. 3 (1996) 62-65.

Google Scholar

[3] P. A. Burke, R. H. Hausler. Assessment of CO2 Corrosion of in the Cotton Valley Lindestone Trend. Mater. Perform. 8 (1985) 726-732.

Google Scholar

[4] J. Ren. The corrosion and protection in Changqing gas field. Nat. Gas Ind. 5 (1998) 63-66.

Google Scholar

[5] H. X. Liu, Y. P. Su. Essential features of tubing corrosion phenomena in Chuandong gas field. Nat. Gas Ind. 5 (2000) 77-80.

Google Scholar

[6] G. Schmitt. CO2 corrosion of carbon steel. Corrosion /84,Houston: NACE, paper No. 1.

Google Scholar

[7] R. C. Woollam, S. E. Hemandez. Assessment and comparison of CO2 corrosion prediction models, SPE Ann. Tech. Conf. Exhibit. 2006. Society of Petroleum Engineers, (2006), pp.245-248.

Google Scholar

[8] C. De Waard, U. Lotz, D. E. Milliams. Predictive model for CO2 corrosion engineering in wet natural gas pipelines. Corrosion, 47(12) (1991) 976-985.

DOI: 10.5006/1.3585212

Google Scholar

[9] J. W. Hu, Response of Seismically Isolated Steel Frame Buildings with Sustainable Lead-Rubber Bearing Isolator Devices Subjected to Near-Fault (NF) Ground Motions. Sustain. 7 (2015) 111-137.

DOI: 10.3390/su7010111

Google Scholar

[10] J. W. Seoet al. Pilot Study for Investigating the Cyclic Behavior of Slit Damper Systems with Recentering Shape Memory Alloy (SMA) Bending Bars Used for Seismic Restrainers, Appl. Sci. 5(3) (2015) 187-208.

DOI: 10.3390/app5030187

Google Scholar

[11] Q. Y. Liu, L. J. Mao, S. W. Zhou, et al. Effects of Chloride Content on CO2 Corrosion of Carbon Steel in Simulated Oil and Gas Well Environments. Corr. Sci. 84 (2014) 165-171.

DOI: 10.1016/j.corsci.2014.03.025

Google Scholar

[12] J. P. Li, G. X. Zhao, Y. Wang. Static Corrosion of Oil Thimble Used in TRIM Oil Field. J. Chinese Soc. Corr. Protect. 4 (2004) 230-233.

Google Scholar