Behavior of Timber-Steel Composite with Dowel Connection under Fire

Article Preview

Abstract:

Recently, a hybrid structure called Timber-Steel Composite (TSC), which is assembled by a central steel I beam with wooden block covered, is expected to introduce a potential strength for the design of modern wooden structure. However, information on this type of structure under the influence of fire is not yet sufficiently explicit to provide designers with a reliable index. The aim of this research was to study the behavior of TSC with dowel connection under fire. Three TSC with bolt connected were tested and were burnt under temperature 700 °C within 10 minutes. Testing results showed that after 10-minute fire burning, the temperature of central I beam is not of great increased, indicating that the wooden block help transmits heat although the dowel connections which connect steel and wood is directly exposed to the fire. It is also observed that dowel connection and air gaps caused a relatively high percentage of char for the wood surrounding the bolt as 13% of total area. In conclusion, a useful prediction on char depth no more than 5cm could be estimated for 1-hour testing validating the purpose of applying TSC in future.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

195-199

Citation:

Online since:

May 2019

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2019 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] W. Winter, K. Tavoussi, T. Pixner, F- R. Parada: Timber-Steel-Hybrid Beams for Multi-storey Buildings. WCTE (2012).

Google Scholar

[2] M. T. Tsai and T. D. H. Le: Determination of Initial Stiffness of Timber–Steel Composite (TSC) Beams Based on Experiment and Simulation Modeling. Sustainability (2018), 10, 1220.

DOI: 10.3390/su10041220

Google Scholar

[3] N. Yasui, M.Koshihara, E.Kosugi, A.Utsumi, T.Sato, Y.Hirano, Y.Ohashi, Development of Wooden Fireproof Building Made of Japanese Cedar,, General Building Research Corporation, Vol.31, No.3, (2006).7, pp.6-16.

Google Scholar

[4] M. Tokoyoda, Y.Fukuda, M.Sudou, T.Yoshikawa, H.Kinjo, T.Hirashima, K.Harada, S.Yusa, K.Saito, Fire Resistance on Hybrid Wooden Structure (Part 21 : Prediction of Internal Temperature Profile on H Shaped Steel Columns Protected by Wood during Fire Resistance Test),, Summaries of Technical Papers of Annual Meeting -Architectural Institute of Japan, (2005).9, pp.133-134.

Google Scholar

[5] E. L. Schaffer, in: A Simplified Test for Adhesive Behavior in Wood Sections Exposed to Fire. U.S.D.A Forest Service Research Note FPL-0174, (1968).

Google Scholar

[6] J. Mena, S. Vera, J. F. Correal, M. Lopez: Assessment of Fire Reaction and Fire Resistance of Guadua Angustifolia Kunth Bamboo, Construction and building material 27 (2012) 60-65.

DOI: 10.1016/j.conbuildmat.2011.08.028

Google Scholar

[7] V. Babrauskas: Charring rate of wood as a tool for fire investigations. Fire Safety Journal 40 (2005) 528–554.

DOI: 10.1016/j.firesaf.2005.05.006

Google Scholar

[8] Fire resistance tests—elements of building construction (ISO 834). Geneva: International Organization for Standardization, (1975).

Google Scholar

[9] Babrauskas V. Charring rate of wood as a tool for fire investigations. Fire Safety Journal (2005); 40, 528–54.

DOI: 10.1016/j.firesaf.2005.05.006

Google Scholar

[10] CNS Standard, CNS 12514. Fire resistant examination for building structural element. Bureau of Standards, Metrology and Inspection, Ministry of Economic Affairs (MOEA), Taipei, Taiwan, (2002).

Google Scholar

[11] R.H. White, E.V. Nordheim: Charring rate of wood for ASTM E119 exposure Fire Technology, 28 (1) (1992), pp.5-30.

DOI: 10.1007/bf01858049

Google Scholar

[12] R.H. White: Charring Rate of Composite Timber Products. Wood and Fire Safety (2000) 353-363.

Google Scholar