Annular Post-Compression by FRP inside Mortar Joints and Vertical Post-Compression by Stainless Steel, for Seismic and Wind Retrofitting of Historical Masonry Chimney

Article Preview

Abstract:

This paper shows the efficiency of the vertical and annular post-compression for wind and seismic structural behavior improvement of slender masonry chimney. For this aim a case study approach regarding an old masonry chimney is used. The paper shows the safety analysis and the safety improvement obtained applying at the same time a vertical and an annular masonry post-compression. The vertical post-compression is obtained through the post-tensioning of twenty-four vertical stainless-steel thin bars. These bars are connected to the chimney masonry only at the basement and at the top. They are placed inside the central void and horizontally distributed along a circumference near the inside face of the masonry, but without to touch it. The annular post-compression is obtained post-tensioning forty-five annular aramidica “not twisted” cables, placed and glued (after the post-tensioning) inside horizontal mortar joints of the more external masonry brick layer.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

642-649

Citation:

Online since:

August 2019

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2019 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] G. Bongiovanni, G. Buffarini and P. Clemente. Dynamic Characterization of Two Earthquake Damaged Bell Towers. Proc., 11thEuropean Conference on Earthquake Engineering, 1998, Paris, 6-11 September (1998).

Google Scholar

[2] M. G. Castellano, M. Indirli, A. Martelli, J. J. Azevedo, G.E. Sincraian, D. Tirelli, V. Renda, G. Croci, M. Biritognolo, A. Bonci and A. Viskovic. Seismic Protection of Cultural Heritage Using Shape Memory Alloy Devices – An EC Funded Project (ISTECH). International Post-SMiRT Conference Seminar on Seismic Isolation, Passive Energy, Dissipation and Active Control of Vibrations of Structures. Cheju, Korea, August 23-25, (1999).

Google Scholar

[3] M. Indirli, B. Carpani, A. Martelli, M. G. Castellano, S. Infanti, G. Croci, M. Biritognolo, A. Bonci, A. Viskovic and S. Viani. Experimental Tests on Masonry Structures Provided with Shape Memory Alloy Antiseismic Devices. 12th World Conference on Earthquake Engineering, Auckland, New Zealand, February (2000).

Google Scholar

[4] F. J. Pallaré, A. Aguero, S. Ivorra. A comparison of different failure criteria in a numerical seismic assessment of an industrial brickwork chimney. Materials and Structures 42: p.213–226, RILEM, Springer, March (2009).

DOI: 10.1617/s11527-008-9379-5

Google Scholar

[5] F. J. Pallaré, S. Ivorra, L. Pallarés, J. Adam. Strengthening Layout Using FRP in Industrial Masonry Chimneys under Earthquake Load. Advanced Materials Research Vols. 133-134, pp.855-859, Trans Tech Publications, Switzerland, (2010).

DOI: 10.4028/www.scientific.net/amr.133-134.855

Google Scholar

[6] S. Ivorra. Old Industrial Masonry Chimneys: Repairing and Maintenance. SAHC2014 – 9th International Conference on Structural Analysis of Historical Constructions, Mexico City, Mexico, 14–17 October (2014).

Google Scholar