Measurement of Glucose in Blood Using a Simple Non Invasive Method

Article Preview

Abstract:

The amount of glucose in blood of human beings should be controlled. The excess or deficiency in glucose of human blood can cause a variety of diseases such as diabetes, heart disease, cholesterol and blindness. We report the design and development of a simple spectrometer as a non-invasive method to determine glucose in urine. Note that glucose in urine, which is caused by exceeding glucose level from the threshold in the renal system, is correlated with that in blood since glucose is a part of acid hydrate in the digestive tract and is absorbed by the intestine in the blood circulation. Urine containing glucose is reacted with a benedict solution that in turn affects the turbidity of urine according to the glucose concentration in the urine. Urines with various turbidities were then placed in transparent containers sitting between a light emitting diode (LED) as a light source and a photodiode as a detector of the simple spectrometer. As the concentration of glucose in the mixture solution became higher, the mixture solution developed more turbid and the output voltage of the photodiode would then be smaller. Moreover, the color of LED affects the magnitude of light intensity that can be transmitted by the sample.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

105-109

Citation:

Online since:

August 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] S.R. Shrivastava, P.S. Shrivastava, J. Ramasamy, Role of self-care in management of diabetes mellitus, J. Diabetes Metabolism. 12 (2013)14.

DOI: 10.1186/2251-6581-12-14

Google Scholar

[2] World Health Organization, Diabetes Factsheet No 132, Geneva (Switzerland), WHO (2011).

Google Scholar

[3] S.Y. Hui Kit, N. M Kassim, Non-invasive blood glucose measurement using temperature-based approach, J. Technol. Sci. Eng. 64 (2013) 105-100.

DOI: 10.11113/jt.v64.2087

Google Scholar

[4] S.Y. Hui Kit, N. M Kassim, Non-invasive blood glucose measurement using temperature-based approach, J. Technol. Sci. Eng. 64 (2013) 105-100.

DOI: 10.11113/jt.v64.2087

Google Scholar

[5] World Health Organization, Diabetes Factsheet No 132, Geneva (Switzerland), WHO (2011).

Google Scholar

[6] S. John, The Pursuit of Noninvasive Glucose: Huntingthe Deceitful Turkey, (2011).

Google Scholar

[7] A. Caduff, E. Hirt, F. Yu, Z. Ali, L. Heinemann, First human experiments with a novel non-invasive, on-optical continuous glucose monitoring system, J. Biosens. Bioelectron. 19 (2003) 209-217.

DOI: 10.1016/s0956-5663(03)00196-9

Google Scholar

[8] T.L. Adamson, F.A. Eusebio, C.B. Cook, J.T. Labelle, The promise of electrochemical impedance spectroscopy as novel technology for the management of patients with diabetes mellitus, Roy. Soc. Chem. 137 (2012) 4179-4187.

DOI: 10.1039/c2an35645g

Google Scholar

[9] R.S. Khandpur, Handbook of Analytical Instruments, Second Edition, Centre for Electronics Design and Tecnology of India, Dept. of Information Tecnology, New Delhi (2006).

Google Scholar

[10] M.M. Munir, A. Rajak, A.Y. Nuryantini, M. Abdullah, Khairurrijal, Fabrication of TiO2/styrofoam composites nanofiber membrane for water purification application, Proceeding of The 5th Nanoscience and Nanotechnology Symposium (NNS), Surabaya, Indonesia (2013).

Google Scholar

[11] A. Wego, Accuracy simulation of an LED based spectrophotometer, J. Opt. 124 (2013) 644-649.

DOI: 10.1016/j.ijleo.2012.01.005

Google Scholar