Powder Metallurgical Synthesis of Biodegradable Mg-Hydroxyapatite Composites for Biomedical Applications

Article Preview

Abstract:

Biodegradable Mg alloys are a new class of temporary implant materials for musculo-skeletal surgery. Recent studies show that Mg-based alloys can be biocompatible and there is a high demand to design Mg alloys with adjustable corrosion rates and suitable mechanical properties. An approach to solving this challenge might be the use of Mg metal matrix composites (Mg-MMC). In this study, a Mg-MMC composed of ZK60 was investigated as the base material and hydroxyapatite (HA) particles were added for tailoring its properties. The composite was produced by high-energy ball milling followed by hot extrusion. This processing route was chosen, as HA in contact with molten Mg releases a toxic gas (phosphine – PH3). The HA particles were homogeneously distributed in the ZK60 matrix after ball milling and the composite was consolidated by hot extrusion. This work presents the influence of different amounts of HA on corrosion behavior and mechanical properties of the composite. Corrosion properties were evaluated by immersion and electrochemical measurements in physiological media at 37 °C. A slight improvement in the corrosion resistance was observed for Mg-MMC due to the presence of more stable corrosion products. Compression tests were used to measure the mechanical properties. Under compression, samples showed a slight increase in the compressive yield strength with the addition of HA, while the ultimate strength did not change significantly.

You might also be interested in these eBooks

Info:

Periodical:

Materials Science Forum (Volumes 828-829)

Pages:

165-171

Citation:

Online since:

August 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Edited by F. Czerwinski, Magnesium alloys – design, processing and properties, InTech: Rijeka, Croatia (2011).

Google Scholar

[2] A. Feng and Y. Han, The microstructure, mechanical and corrosion properties of calcium polyphosphate reinforced ZK60A magnesium alloy composites, Journal of Alloys and Compounds 504 (2010) 585-593.

DOI: 10.1016/j.jallcom.2010.06.013

Google Scholar

[3] Z. Li, Mg/Hydroxyapatite composites for potential bio-medical applications, PhD thesis, Brunel University, London, (2010).

Google Scholar

[4] N.T. Kirkland and N. Birbilis, Magnesium biomaterials: design, testing, and best practice, Springer International Publishing, (2014).

Google Scholar

[5] W.F. Ng, K.Y. Chiu and F.T. Cheng, Effect of pH on the in vitro corrosion rate of magnesium degradable implant material, Materials Science and Engineering: C (2010) 898-903.

DOI: 10.1016/j.msec.2010.04.003

Google Scholar

[6] J. Kuhlmann, I. Bartsch, E. Willbold, S. Schuchardt, O. Holz, N. Hort, D. Höche, W.R. Heineman and F. Witte, Fast escape of hydrogen from gas cavities around corroding magnesium implants, Acta Biomaterialia 9 (2013) 8714-8721.

DOI: 10.1016/j.actbio.2012.10.008

Google Scholar

[7] M.P. Staiger, A.M. Pietak, J. Huadmai and G. Dias, Magnesium and its alloys as orthopedic biomaterials: a review, Biomaterials 27 (2006) 1728-1734.

DOI: 10.1016/j.biomaterials.2005.10.003

Google Scholar

[8] G. Song, Control of biodegradation of biocompatable magnesium alloys, Corrosion Science 49 (2007) 1696-1701.

DOI: 10.1016/j.corsci.2007.01.001

Google Scholar

[9] F. Witte, J. Fischer, J. Nellesen, H.A. Crostack, V. Kaese, A. Pisch, F. Beckmann and H. Windhagen, In vitro and in vivo corrosion measurements of magnesium alloys, Biomaterials 27 (2006) 1013-1018.

DOI: 10.1016/j.biomaterials.2005.07.037

Google Scholar

[10] F. Witte, F. Feyerabend, P. Maier, J. Fischer, M. Störmer, C. Blawert, W. Dietzel, N. Hort, Biodegradable magnesium-hydroxyapatite metal matrix composites, Biomaterials 28 (2007) 2163-2174.

DOI: 10.1016/j.biomaterials.2006.12.027

Google Scholar

[11] M.J. Shen, X.J. Wang, C. D Li, M.F. Zhang, X.S. Hu, M.Y. Zheng and K. Wu, Effect of bimodal size SiC particulates on microstructure and mechanical properties of AZ31B magnesium matrix composites, Materials and Design 52 (2013) 1011-1017.

DOI: 10.1016/j.matdes.2013.05.067

Google Scholar

[12] S. Tiwari, R. Balasubramaniam and M. Gupta, Corrosion behavior of SiC reinforced magnesium composites, Corrosion Science 49 (2007) 711-725.

DOI: 10.1016/j.corsci.2006.05.047

Google Scholar

[13] R. Relttig and S. Virtanen, Time-dependent electrochemical characterization of the corrosion of a magnesium rare-earth alloy in simulated body fluids, Journal of Biomedical Materials Research A85 A(2008)167-175.

DOI: 10.1002/jbm.a.31550

Google Scholar

[14] DIN 50106, Testing of Metallic Materials; Compression Test (1978).

Google Scholar

[15] ISO10993-5, Biological evaluation of medical devices - Part 5: Tests for cytotoxicity: In vitro methods, International Standards Organization, Geneva (1993).

Google Scholar

[15] M.A. Azeem, A. Tewari, S. Mishra, S. Gollapudi, U. Ramamurty, Development of novel grain morphology during hot extrusion of magnesium AZ21 alloy, Acta Materialia 58 (2010) 1945-1502.

DOI: 10.1016/j.actamat.2009.10.056

Google Scholar

[16] X. Wang, X. Hu, K. Nie, K. Wu, M. Zheng, Hot extrusion of SiCp/AZ91 Mg matrix composites, Trans. Nonferrous Met. Soc. China 22 (2012) 1912-(1917).

DOI: 10.1016/s1003-6326(11)61407-6

Google Scholar

[17] A. Feng and Y. Han, Mechanical and in vitro degradation behaviour of ultrafine calcium polyphosphate reinforced magnesium-alloy composites, Materials and Design 32 (2011) 2813-2820.

DOI: 10.1016/j.matdes.2010.12.054

Google Scholar

[18] X. Gu, W. Zhou, Y. Zheng, L. Dong, Y. Xi, D. Chai, Microstructure, mechanical property, bio-corrosion and cytotoxicity evaluations of Mg/HA composites, Materials Science and Engineering C 30 (2010) 827-832.

DOI: 10.1016/j.msec.2010.03.016

Google Scholar