Electric Field Numerical Simulation on the Magnesium Alloy Quantitative Transmission of Direct Current Electromagnetic Pump

Article Preview

Abstract:

According to the electromagnetic pump in Magnesium Alloy Casting Experiments Center of University of Science and Technology Liaoning, with the help of ANSYS software, we realized three-dimensional simulation of electric field of the pump by finite element analysis method, and calculated the distribution of electric field generated by five data sets , whose slot length and width were 30mm, 50 mm, 60 mm, 70 mm and 80 mm. We have explored how different runner dimensions affected electric field distribution in electromagnetic field, and simulated the distribution of current density. The optimal size of the runner is 50mm according to the current density distribution.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

211-214

Citation:

Online since:

November 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Jiang Guochang, Wu Yongquan: The Molten Metal Physics Preliminary, Metallurgical Industry Press(2012), p.132.

Google Scholar

[2] Hu Renxi, Sun Mingli: ANSYS13. 0 Electromagnetic Finite Element Analysis from Entry to Master,  China Machine Press(2011), pp.1-6, 14-17.

Google Scholar

[3] Xie Longhan, Geng Yu, Qiu Wan: ANSYS Electromagnetic Field Analysis, Electronic Industry Press(2012), pp.1-4.

Google Scholar

[4] Ma Yurong: Numerical Simulation of Temperature Field in The Furnace of Magnesium Alloy Insulation, DongBei University Publising (2008).

Google Scholar