Electric Field Numerical Simulation on the Magnesium Alloy Quantitative Transmission of Direct Current Electromagnetic Pump
Abstract:
According to the electromagnetic pump in Magnesium Alloy Casting Experiments Center of University of Science and Technology Liaoning, with the help of ANSYS software, we realized three-dimensional simulation of electric field of the pump by finite element analysis method, and calculated the distribution of electric field generated by five data sets , whose slot length and width were 30mm, 50 mm, 60 mm, 70 mm and 80 mm. We have explored how different runner dimensions affected electric field distribution in electromagnetic field, and simulated the distribution of current density. The optimal size of the runner is 50mm according to the current density distribution.
Info:
Periodical:
Pages:
211-214
Citation:
Online since:
November 2015
Authors:
Price:
Сopyright:
© 2015 Trans Tech Publications Ltd. All Rights Reserved