Eddy Current and Metal Magnetic Memory Testing Nondestructive Evaluation for Superficial Defects of Old Cylinder Barrel

Article Preview

Abstract:

Eddy current testing and metal magnetic memory testing, cooperated with special testing devices, were applied to detect the superficial defects of old cylinder barrel. It was indicated that there were three types of the signals, which were non-defect signals, discontinuous peak signals and continuous peak signals. Non-defect signals indicated that there was no defect in cylinder barrel, and the discontinuous peak signals denoted that there was circumferential cracking, and the continuous peak signals showed that there was longitudinal cracking in the surface of cylinder barrel. The amplitude of eddy current testing signals characterizes the depth of cracking, and the gradient of magnetic signals descript the degree of stress concentration. The method mentioned above detects the cracking and stress concentration in the superficial coat of old cylinder barrel, which effectively guarantee the quality of automobile cylinder.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

107-112

Citation:

Online since:

March 2016

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2016 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] L.H. Dong, S.Y. Dong, B.S. Xu, Investigation of metal magnetic memory signals from the surface of low-carbon steel and low-carbon alloyed steel, J. Cen. Sou. Uni. Tech. 14(2007) 24-27.

DOI: 10.1007/s11771-007-0005-4

Google Scholar

[2] G. Dobmann, L.G. Debarberis, J. F. Coste, Aging material evaluation and studies by non-destructive techniques (AMESNDT) – a European network project, Nucl. Eng. Des. 206(2001) 363-374.

DOI: 10.1016/s0029-5493(00)00422-2

Google Scholar

[3] M.A. Jiboory, D.G. Lord, Y.J. Bi, Magnetic domains and microstructural defects in Terfenol-D, J. Appl. Phys. 73(1993) 61-68.

Google Scholar

[4] A.A. Doubov, A Technique for Monitoring The Bends of Boiler and Steam-Line Tubes Using The Magnetic Memory of Metal, Therm. Eng. 48(2001) 289-295.

Google Scholar

[5] N. Li, B.P. Du, The effect of low-stress high-cycle fatigue on the microstructure and fatigue threshold of a 40Cr steel, Int. J. Fatigue. 17(1995) 43-48.

DOI: 10.1016/0142-1123(95)93049-8

Google Scholar

[6] C.L. Shi, W.X. Tang, H. Zhan, Characterization of Crack Initiation Life in Ferromagnetic Material by Metal Magnetic Memory Testing, M.S.F. 817(2015) 791-796.

DOI: 10.4028/www.scientific.net/msf.817.791

Google Scholar

[7] X.L. Zheng, On some basic problems of fatigue research in engineering, Int. J. Fatigue. 23 (2001) 751-766.

DOI: 10.1016/s0142-1123(01)00040-8

Google Scholar

[8] R.M. Hornreich, H. Rubinstein, R.J. Spain, Magnetostrictive phenomena in metallic materials and some of their device applications, IEEE Trans. Magn. 7(1971) 29.

DOI: 10.1109/tmag.1971.1067004

Google Scholar

[9] Chechko Π, Using the method of magnetic memory of metal to evaluate the service life of the items of power equipment at the Konakovo District Power station, Therm. Eng. 49(2002) 1028.

Google Scholar

[10] C.L. Shi, P. He, S.Y. Dong, Distinguishing Stress Concentration or Cracking in Ferromagnetic Material Using Abnormal Magnetic Signals, Mater. Trans. 54(2013) 1102-1104.

DOI: 10.2320/matertrans.m2012393

Google Scholar