Removal of Iron and Manganese Using Cascade Aerator and Limestone Roughing Filter

Article Preview

Abstract:

Combination between oxidation and filtration can be used for removing iron and manganese from groundwater especially when the concentrations of these metals were high. This study focused on the effectiveness of the cascade aerator and the size of the limestone filter media to remove iron and manganese from groundwater. Water samples used for this study were collected from orphanage home, Rumah Nur Kasih, Taiping. Universiti Sains Malaysia (USM) has provided a tube well of 15 m depth and 150 mm diameter for the orphanage home. However, the water cannot be used for domestic consumption due to high amount of iron and manganese at 6.48 and 1.9 mg/L which exceeded the drinking water standard of 0.3 and 0.1 mg/L respectively. Using laboratory physical model, the study has shown that the removals of iron and manganese have reduce the concentration until 0.17 and 0.2 mg/L respectively. Thus, the results from this study which utilize cascade aerator and limestone roughing filter could be implemented on site for the community to use the ground water for domestic purposes.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

509-513

Citation:

Online since:

May 2016

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2016 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Onyeka Nkwonta and George Ochieng, Roughing Filter for Water Pre-Treatment Technology in Developing Countries: A Review, International Journal of Physical Sciences, Vol. 4(9), 455-463, (2009).

Google Scholar

[2] Elena Lopez-Gun and W. Todd Jarvis, Groundwater Governance and The Low of The Hidden Sea, Water Policy II, 742-762, (2009).

Google Scholar

[3] V. Rathinakumar, G. Dhinakaran and C. R. Suribabu, Assessment of Aeration Capacity of Stepped Cascade System for Selected Geometry, vol. 6, no. 1, pp.254-262, (2014).

Google Scholar

[4] Rein Munter, Heldi Ojaste and Johannes Sutt, Complexed Iron Removal from Groundwater, Journal of Environmental Engineering ©ASCE, 131: 1014-1020, (2005).

DOI: 10.1061/(asce)0733-9372(2005)131:7(1014)

Google Scholar

[5] Interim National Water Quality Standards for Malaysia, (2010). <http: /www. wepa-db. net/policies/law/malaysia/eq_surface. htm>. [Revised December 2010].

Google Scholar

[6] Aziz HA, Smith PG. The Influence of pH and Coarse Media on Manganese Precipitation from Water. Water Res 1992; 26; 853-5.

DOI: 10.1016/0043-1354(92)90017-x

Google Scholar

[7] Aziz HA, Smith PG. Removal of Manganese from Water using Crushed Dolomite Filtration Technique. Water Res 1996; 2; 489-92.

DOI: 10.1016/0043-1354(95)00178-6

Google Scholar