The Analysis of the Mechanics Performance about GFRP Tube Confined Concrete Short Column under the Axial Compression

Article Preview

Abstract:

In order to study the axial compression performance of GFRP tube composite columns filled with concrete and better applied to engineering, the influence of different winding angle of GFRP tube, thickness of GFRP tube, concrete strength and the containing rate of steel are simulated by using finite element analysis software ABAQUS when the column under the axial compression ,The results show that: the numerical results are in good agreement with the experimental results; reduced GFRP tube winding angle, increasing the GFRP tube thickness, improve the core concrete strength and an increase in steel containing rate could increase the bearing capacity of columns.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

160-165

Citation:

Online since:

July 2016

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2016 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Yulei Liu, The performance test research of GFRP tube, concrete, concrete filled steel tube composite column under axial compression . 2007, Dalian University of Technology.

DOI: 10.21276/sjet.2016.4.7.6

Google Scholar

[2] Keya Yang, Qingyang Liu, The seismic performance experimental research of GFRP tube filled with concrete. Journal of Changchun College of Engineering :Natural Science,2008, 6(01): 29-31.

Google Scholar

[3] Hu, Y.M., T. Yu, and J.G. Teng, FRP-Confined Circular Concrete-Filled Thin Steel Tubes under Axial Compression. Journal of Composites for Construction, 2011. 15(5): 850-860.

DOI: 10.1061/(asce)cc.1943-5614.0000217

Google Scholar

[4] Ni Zhang, Lianguang Wang, Jianping Wen , The research of GFRP hollow tube filled with high strength concrete column under axial compression. Journal of Dongbei University: Natural Science. 2013, 34(07): 1049-1052.

Google Scholar

[5] Qing Yu, The stress-strain relationship study of FRP confined concrete under the axial compression. Industrial Architecture, 2001, 31(04): 5-8.

Google Scholar

[6] Zhitao Lv , Gang Wu , The study of FRP confined concrete columns stress-strain relations with no softened period . Journal of Building Structures, 2003, 24(05): 1-9.

Google Scholar

[7] Jiaru Qian , Mingxue Liu , The compression stress strain model of FRP constraints the cylindrical concrete column. China Civil Engineering Journal, 2006, 39(11): 1-6.

Google Scholar

[8] Guochang Lu, Lieping Ye, The research of stress-strain relationship of FRP confined concrete under the axial compression. Engineering Mechanics, 2006, 23(09): 98-103.

Google Scholar

[9] Lam,L.;J.G. Teng, Design-oriented stress–strain model for FRP-confined concrete. Construction and Building Materials, 2003. 17(6-7): 471-489.

DOI: 10.1016/s0950-0618(03)00045-x

Google Scholar

[10] Hashin Z, Fatigue failure criteria for unidirectional fiber composites. Journal of Applied Mechanics, 1981, 48(4): 846-852.

DOI: 10.1115/1.3157744

Google Scholar

[11] Guanlin Shen, Compound Material Mechanics, Tsinghua University Press, (2006).

Google Scholar

[12] Guopeng Qin, The mechanical properties research of GFRP tube reinforced concrete member, 2010, Dongbei University.

Google Scholar

[13] Guopeng Qin, Lianguang Wang, Le Zhou , The compression performance study of GFRP tube composite column under the axial compression. Industrial Architecture, 2009, 26(10): 72-75.

Google Scholar

[14] Bailing Chen, Guopeng Qin, Lianguang Wang , The axial compression bearing capacity of GFRP tube steel reinforced concrete short column. Journal of Dongbei University :Natural Science. 2010, 31(07): 1035-1038.

Google Scholar

[15] Lianguang Wang, Guopeng Qin , Le Zhou , The experiments study of GFRP tube steel reinforced high strength concrete composite column under axial compression. Engineering Mechanics, 2009, 26(09): 170-185.

DOI: 10.21276/sjet.2016.4.7.6

Google Scholar