Selection Criteria of Optimal Characteristic Material and Technologies for Precision Processing of Basic Working Surface of Human Hip-Joint Implant

Article Preview

Abstract:

In view of the fact that the endo-prosthesis heads of human hip-joint are operated in extreme conditions, in respect of load, the selection of corresponding material and also increase of precision and quality of machining of spherical surfaces is rather topical task.In the submitted work are reviewed the problems connected with definition of the influence degree of orientation of the sapphire crystal on its workability during diamond grinding with a butt of the ring and elaboration of the perspective, original scheme of formation of the incomplete spherical surface, particularly, of the sapphire head of endo-prosthesis of the human hip-joint.

You might also be interested in these eBooks

Info:

Periodical:

Solid State Phenomena (Volume 261)

Pages:

28-35

Citation:

Online since:

August 2017

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2017 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Batiashvili B.I., Butskhrikidze D.S., Mamulashvili G. A, Turmanidze R.S., Kromp K., Mills B., Mgaloblishvili O. Technological Possibilities of Low Temperature Precision Grinding Process when Machining Hard and Brittle Materials. Fractography of advanced ceramics, International Conference, Stará Lesná, High Tatras, May (2001).

DOI: 10.4028/www.scientific.net/kem.223.149

Google Scholar

[2] Turmanidze R. S, Butskhrikidze D. S, Kromp K., Mills B., Low temperature precision grinding of hard and brittle materials,. Problems of mechanics and physico-chemistry of the process of abrasive machining, Kiev 2002, pp.490-499.

DOI: 10.4028/www.scientific.net/kem.223.149

Google Scholar

[3] Rozenberg O. A, Sokhan S.V., Vozny V.V., Mamalis A.G., Gavlik J., Kim D-J. Trends and Development in the Manufacturing of Hip Joints: An Overview Int. J. Adv. Manuf. Technology (2006) 27: pp.537-542.

DOI: 10.1007/s00170-004-2189-1

Google Scholar

[4] Lieberman J R, Two Alternative Bearings for Total Hip Arthroplasty: More Data Are Needed. J Am Acad Orthop Surg 2009; pp.61-62.

Google Scholar

[5] Dobrovinskaya E., Litvinov L., Pishchik V. Mono-crystals of corundum – К: Science, 1994. – 256 p.

Google Scholar

[6] Turmanidze R.S. Implants of the human hip joints and peculiarities of their manufacture with the high precision and quality of machining of the work surfaces. Proceedings of the 13th International Conference on Tools, ICT 2012. 27-28 march 2012. University of Miskolc, Hungary. Session (B).

Google Scholar