Assessment of Fire Safety of Coatings Based on Silicate Paint Sol

Article Preview

Abstract:

The results of the study the fire safety of coatings, based on silicate and sol silicate paints, are presented. The rapid method of the fire tube (based on the definitions of the duration of self-combustion or smoldering and on the mass loss of the sample after exposure to an open flame) established that the coatings belong to the group of non-flammable material, for coatings, based on poly-silicate solutions, have a lower loss of mass, in comparison with coatings based on liquid glass. At the flammability test on the TPR it was established, that coating based on potassium liquid glass and potassium poly-silicate solution did not ignite seen, even at a temperature of 760 degrees. There is no smoke emission. However, a change in the shape and color was recorded. The weight loss of the sample of the coating, based on potassium liquid glass, was 30.14% by weight, and the coating sample, based on the potassium poly-silicate solution, was 27.14%. The evidence of improvement of fire hazard characteristics of coatings based on poly-silicate solutions is obtained.

You might also be interested in these eBooks

Info:

Periodical:

Solid State Phenomena (Volume 299)

Pages:

200-204

Citation:

Online since:

January 2020

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2020 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] V.I. Korneev, V.V. Danilov, Production and use of soluble glass, L.: Stroiizdat, (1991).

Google Scholar

[2] P. Eiler, Chemistry of silica, V2, vol. T. M .: Mir, (1982).

Google Scholar

[3] Preparation and use of silica hydrosols. Ed. Prof. FrolovaYu.G. Proceedings of the Moscow Art Theater. Mendeleyev, (1979).

Google Scholar

[4] O. Figovsky, Yu. Borisov, D. Beilin, Nanostructured Binder for Acid-Resisting Building Materials. J. Scientific Israel-Technological Advantages 14(2012) 7–12.

Google Scholar

[5] V.I. Loganina, S.N. Kislitsyna,Ye. B. Mazhitov, Development of sol-silicate composition for decoration of building walls. Case Studies in Construction Materials 9 (2018).

DOI: 10.1016/j.cscm.2018.e00173

Google Scholar

[6] V.I. Loganina, S.N. Kislitsyna,Ye. B.Mazhitov, Properties of Polysiylate Binders for Sol-Silicate Pains. Advanced Materials Research Submitted: (2018).

DOI: 10.4028/www.scientific.net/amr.1147.1

Google Scholar

[7] V.I. Loganina , Y.B. Mazhitov. Polysilicate binder for silicate paints. Bulletin of Perm National Research Polytechnic University. Construction and architecture. 9(2018) 39-45.

Google Scholar

[8] Bilotta Antonio, de Silva Donatella, Nigro Emidio,General approach for the assessment of the fire vulnerability of existing steel and composite steel-concrete structures . Journal of building engineering 8 (2016) 198-207.

DOI: 10.1016/j.jobe.2016.10.011

Google Scholar

[9] Krueger Simone, Gluth Gregor J. G, Watolla Marie-Bernadette, New ways: Reactive fire protection coatings for extreme conditions .Bautechnik 93(2016) 531-542.

Google Scholar

[10] R. Velicka, E. Velickova, Assessment of the Normative Requirements for Ensuring the Safety of Powder Coating Booths in Terms of the Risk of Explosion. Proceedings of the 9th international scientific symposium on electrical power engineering. slovakia (2017) 359-364.

Google Scholar

[11] Sedlak Bartlomiej, Kinowski Jacek, Sulik Pawel. The risks associated with falling parts of glazed facades in case of fire .Open engineering 8 (2018) 147-155.

DOI: 10.1515/eng-2018-0011

Google Scholar

[12] Thompson Owain F., Galea Edwin R., Hulse Lynn M. A review of the literature on human behaviour in dwelling fires. Safety science 109 (2018) 303-312.

DOI: 10.1016/j.ssci.2018.06.016

Google Scholar

[13] GOST 12.1.044-89 Occupational safety standards system. Fire-fighting measures of substances and materials.Nomenclature of indicators and methods for determining them,.

Google Scholar

[14] GOST 30244-94 Building Materials - Methods of Testing for Combustibility,.

Google Scholar

[15] GOST 30402-96 Construction materials - Test method for flammability,.

Google Scholar

[16] Technical regulations on the requirements of fire safety [Electronic resource]: Feder. the law of Ros. Federation of July 22, 2008 No. 123-FZ: adopted by the State. The Duma of Feder. Coll. Ros. Federation on July 4, 2008: approved. Federation Council Feder. Coll. Ros. Federation on July 11, 2008 (in the version of the Federal Law of July 3, 2016 No. 301-FZ).

DOI: 10.2753/rsd1061-0014430301

Google Scholar

[17] Yang, Hongyu, Jiang Yuping, Liu, Hongyin. Mechanical, thermal and fire performance of an inorganic-organic insulation material composed of hollow glass microspheres and phenolic resin. Journal of colloid and interface science 530 (2018) 163-170.

DOI: 10.1016/j.jcis.2018.06.075

Google Scholar

[18] Wang Yali, Yan Fangyou, Jia Qingzhu. Distributive structure-properties relationship for flash point of multiple components mixture. Fluid phase equilibria. 474 (2018) 1-5.

DOI: 10.1016/j.fluid.2018.07.005

Google Scholar

[19] V. D Thi, M. Khelifa, M.Oudjene, Numerical simulation of fire integrity resistance of full-scale gypsum-faced cross-laminated timber wall. International journal of thermal sciences . 132 (2018) 96-103.

DOI: 10.1016/j.ijthermalsci.2018.06.003

Google Scholar

[20] Wei Ruichao, He Yaping, Zhang Zheng. Effect of different humectants on the thermal stability and fire hazard of nitrocellulose. Journal of thermal analysis and calorimetry 133 (2018) 1291-1307.

DOI: 10.1007/s10973-018-7235-6

Google Scholar