Search Options

Sort by:

Sort search results by

Publication Type:

Publication Type filter

Open access:

Publication Date:

Periodicals:

Periodicals filter

Search results

Online since: September 2013
Authors: Miao Yu, Nan Qing Zhang, Xia Zhang, Hong Song Wu, Jie Fu
Enhancing Tower Crane Safety Using Condition Monitoring System Nanqing Zhang1,a, Miao Yu2,b ,Xia Zhang3,c,jie Fu4,d,Hongsong Wu5,e 1Research Center of Sensing and Instrumentation Technologies, College of Optoelectronic  Engineering, Chongqing University, Chongqing 400044, China 2College of Optoelectronic Engineering, Chongqing University, Chongqing 400044, People’s Republic of China, aznqjob@gmail.com, byumiao@cqu.edu.cn Keywords: tower crane, CMS, safety, alarm, CDMA Abstract.
Behzadan, A real time decision support system for enhanced crane operations in construction and manufacturing, 2011 ASCE International Workshop on Computing in Civil Engineering Miami, Florida, Jun. 20–22, 2011,pp. 586–593
Online since: March 2013
Authors: Ming Liu, Xin Hai Fan, Lin Liu
Analysis on Reinforcement and Design of a Historic Building Retrofitting Project LIU Ming1,a,FAN Xin-hai2,b, LIU Lin1,c 1School of Civil Engineering, Shenyang Jianzhu University, Shenyang 110168, China 2Technology Center,China Construction Eighth Engineering Division,Shanghai 200120,China aemail:liumingsy2008@163.com, bemail:fanxinhai521@163.com, cemail: 117022428@qq.com Keywords: Historic building; Retrofitting; Reinforcement; Inner frame; Planting bar.
Structural Engineers,2011,27(3):62-66(in chinese).
Online since: April 2015
Authors: Qiu Juan Lv, Chen Jiang Cao, You Jun Wang
After that, the engineering data and the boundary conditions should be set as described above.
Design of a small-scale autonomous amphibious vehicle[C].2008 Canadian Conference on Electrical and Computer Engineering – CCECE, Niagara Falls, Canada,2008:781-786
Archives of Civil and Mechanical Engineering, 2008, (1):97-105
Online since: September 2011
Authors: Xue Dong Chen, Hai Yan Song, Zong Min Liu, Ji Ze Mao
Study on gradient-dependent nonlocal damage constitutive models of concrete under freeze-thaw action LIU Zongmin1, a, MAO Jize1, b, SONG Haiyan1, c, CHEN Xuedong2, d 1 Smart Structures and Advanced Composites Laboratory, College of Aerospace and Civil Engineering, Harbin Engineering University, Harbin 150001, China 2 Heilongjiang Research Institute of Electric Power Exploration and Design, Harbin 150010, China a lzm1976@yahoo.com.cn, bmaojize@hrbeu.edu.cn, cshyivg@yahoo.com.cn, dcxd0451@163.com Keywords: gradient-dependent, nonlocal, damage, freeze-thaw Abstract.
[4] Zongmin Liu, Jize Mao and Haiyan Song: Study on Non-local Damage Constitutive Model of Concrete under Freeze-thaw Action, Key Engineering Materials, 2011, vols.452-453, pp.133-136
Online since: September 2011
Authors: Zhe Qin, Lei Wang, Li Bo Meng
An Optimization Model of Extension Sets on Supporting Scheme for Foundation Pit and its Application Zhe Qin1,a , Lei Wang1,b, Li-bo Meng1,c 1College of Civil Engineering and Architecture, Shandong University of Science and Technology, Qingdao 266510, China a wls3016@163.com , b swiftness_99@live.cn , c menglibo161@163.com Keywords: supporting scheme for foundation pit, matter element analysis, extension sets, relational function Abstract: This paper aims at the incompatibility of indices in comprehensive evaluation of supporting scheme for foundation pit.
But in engineering practice, we usually broaden the classical field x0i appropriately considering the indexes not all best.
FENG Yuguo,Geotechnical Engineering Technique,(1):38-40(2001).
Online since: December 2012
Authors: Xue Wang, Yu Min Yan, Li Hong Yao, Yong Jun Liu
Development of Thermal Resistance Elements for Thermal Analysis of Composite Structural Members in Fires Yongjun Liu1, a, Yumin Yan2,b, Lihong Yao 2,c, Xue Wang2,d 1 School of Civil Engineering, Shenyang Jianzhu University, Shenyang, 110168, China 2 Higher Vocational Technical College, Shenyang Agricultural University, Shenyang, 110866, China aliuyongjun1966@163.com, byym1963@163.com, cylh1970@163.com dwx1980@163.com Keywords: Thermal resistance element, Composite structural member, Interface, Fire Abstract.
●The value of thermal resistance Ω of interfaces depend on such factors as temperature during a real fire, as a result, further experimental work is needed to determine the relations between thermal resistance and time, which will provide scientific basis for accurate analysis and engineering design.
International Journal for Numerical Methods in Engineering.
Online since: December 2014
Authors: Shi Guo Sun, Jun Hui Zhang
Engineering Geology, 1980, 16: 51~61
Theory of globally critical slip field of slopes and its application to practical engineering [J].
China Civil Engineering Journal, 1999, 32(3): 66-72.
Online since: June 2014
Authors: Xiao Long Zhang, Shang Liu
It has found extensive application in civil engineering, machinery, aviation and other fields, and has been partly used in practical engineering cases [3-4].
Journal of Engineering Mechanics,ASCE,1997,(123):897- 971
Online since: December 2014
Authors: Tao Zou, Yu Lai Han
Bond strength between steel and concrete experiment analysis at different temperatures Tao Zoua, Yulai Han Aerospace and Civil Engineering, Harbin Engineering University, Harbin, 150001, China aEmail: zhoutaotao@163.com Keywords: Different temperatures, Reinforced concrete, Bond strength, Experiment Analysis.
Therefore, under different temperature bond strength between steel and concrete and bond segment free end slip values, reinforced concrete fire protection, fire resistance engineering research has important significance.
Online since: January 2012
Authors: Guo Liang Zhao, Jin Ming Dong, Xi Kang Yan
Study of mechanical property of column with Construction seam JinMing Dong1,a , XiKang Yan 1,2,b , GuoLiang Zhao 1,c 1Civil engineering college of hebei university of Technology,Tian jin 300401,,china 2Research center of civil engineering technology of Hebei province,Tian jin 300401,,china ats522741225@163.com ,btisyxk@126.com, ctjszgl@126.com Keywords: Construction seam;Seismic performance;Limit load.
Journal of building water conservancy and engineering,2010,8(1):160-163