Search:

  • grain number

Search Options

Sort by:

Publication Type:

Open access:

Publication Date:

Periodicals:

Search results

Online since: February 2015
Authors: Madzlan Aziz, Muhazri Abd Mutalib, Ahmad Fauzi Ismail, Mohd Hafiz Dzarfan Othman, Juhana Jaafar, Mukhlis Abdul Rahman
The performance of cathode in SOFC can be enhanced by manipulating its layer characteristics, including pore and grain sizes, pore distribution and porosity [3].
Acknowledgements The authors gratefully acknowledge financial support from Sciencefund (Project Number: R.J130000.7942.4S033), Research University Grant ((Project Number: Q.J130000.2542.03H14), Research University Grant ((Project Number: Q.J130000.2509.05H53), Ministry of Science, Technology and Innovation (MOSTI), Ministry of Education Malaysia (MOE) and technical and management support from Research Management Centre, Universiti Teknologi Malaysia.
Online since: August 2017
Authors: Chuan Zhen Huang, Jun Wang, Rong Guo Hou, Hong Tao Zhu, Huan Yang
In theory, most of proposed theories and laws are based on too many hypotheses such as time mean and special grain shape, their application is limited.
This model is mathematically given by (3) (4) where, , , is the generation of the turbulent kinetic energy duo to the mean velocity gradient, μ is the dynamic viscosity (Pa-s), k is the turbulent kinetic energy(J), ε is the dissipation rate, S is the flow source , is the generation of the turbulent kinetic energy duo to buoyancy, is the affection coefficient of the compressible turbulent pulsation expansion on the total dissipation rate, and are constant, and are the turbulent Prandtl numbers for k and ε.
AWJ Nozzle Air Domain omain Target Figure 1 Physical model of abrasive water jet machining To investigate the accuracy, stability and convergence properties of the CFD model, a number of initial computations were performed using the first upwind method and the second upwind method.
The relaxing number is selected according to the converging condition.
Online since: June 2012
Authors: Hong Xiang Zhai, Zhen Ying Huang, Shi Bo Li, Yong Zheng, Jin Rong Lu, Yang Zhou
There are three zones with different contrast in the SEM photograph, i.e. dark zone (around number 1), grey zone (around number 2) and white zone (around number 3), and the grey zone is between the dark zone and the white zone.
With carefully observations, the Ti3SiC2 grain size is between 5μm ~15μm and distributes uniformly in the Cu matrix.
Online since: June 2005
Authors: Ji Yong Chen, Ping Yang, H. Sun, Yong Xiang Leng, An Sha Zhao, Nan Huang, Lan Xin Xu, Jin Wang
The film surface is very smooth and compact, with grain size less than 100 nm.
Our platelet adhesion studies illustrate that the number of adhered platelets is smallest on sample #4, as shown in Fig. 3.
One can see that the number of platelets adhered onto the #4 film was markedly less than that for the others.
Number of platelets adhered on titanium oxide films and on LTIC (incubation time = 120 minutes). 4.
Online since: January 2012
Authors: Qing Wang, Jing Da, Zhao Yang Ding, Zhi Tong Sui, Cun Bao Zhang
Gravel was continuous grading with grain size between 5mm~31.5mm.
After demoulding and numbering, wire brush was used to roughen both ends of samples, no less than 20mm protective mortar layers added at both ends were necessary.
Table3 Corrosion weightless rates of reinforcing steel bar and carbonation depth of reinforced geopolymer concrete number n(SiO2)/ n(Al2O3) n(Na2O)/ n(Al2O3) n(H2O)/ n(Na2O) Mass standard of steel bar/g Carbonation depth/mm Weight of rusted steel bar/g corrosion weightless rates /% 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 3.3 3.5 3.7 3.9 4.1 4.3 4.5 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.3 0.4 0.5 0.3 0.3 0.3 0.3 0.3 0.3 31 31 31 31 31 31 31 31 31 31 31 26 28 31 34 36 39 74.1075 72.8925 74.3946 71.1501 75.5154 72.6123 73.8195 74.7510 69.9312 73.4335 76.3806 73.9449 74.7576 72.8967 73.9494 76.6512 72.8883 2.52 2.48 2.50 1.76 1.57 1.28 1.46 3.34 2.22 1.74 1.68 1.58 1.06 1.74 2.09 2.96 3.44 73.8936 72.6892 74.2022 71.0085 75.3881 72.5114 73.7097 74.4904 69.7289 73.3097 76.2978 73.8793 74.6465 72.7590 73.7729 76.4225 72.5320 0.28 0.27 0.25
However, alkalinity of concrete will be reduced with over-growth of n(H2O)/n(Na2O) which not only ruin the base enviroment but also increase the number of pores inside the concrete .
Online since: May 2020
Authors: Zhi Shou Zhu, Tao Jiang, Xin Nan Wang, Jing Li, Yun Peng Xin
A large number micro-pores and micro-cracks originating from the adiabatic shear bands expanded, forming macroscopic cracks.
Some adiabatic shear bands extending upwards along penetration direction and a large number deformed structure were observed on the verge of penetration, as seen in Fig. 5 (b).
A large number micro-pores and micro-cracks originating in the adiabatic shear bands cause the fracture of alloy
[22] Z Wang, X N Wang, LW Zhu, ZS Zhu, Grain Growth behavior in β single phase of TB17 titanium alloy.
Online since: August 2008
Authors: G. de Vasconcelos, J.L. dos Reis, M.V. Campanha, A.F. da Silva
The laser beam power was fixed at 50W and the number of runs (superposition of tracks) varied on the sample.
Fig. 1: MEV of the starting material, thin graphite powder with 3 micrometers of average grain size.
As can seen in Table 1, the AISI M2 samples were irradiated with two different laser beam sweep speed values, whereas each one of them was irradiated a certain number of times or number of heating cycles, which are 3, 10 and 20 times.
Fig. 4 shows the dependence of the laser intensity and the number of irradiations of a sample covered by a graphite layer.
Normal loads: 5N, track size: 6 [mm], pin sliding velocity: 10 [cm/s], turn's number: 2000, time of test: 13'14".
Online since: January 2010
Authors: Jun Hua Gu, Jie Song, Na Zhang, Yan Liu Liu
In this paper, it's simple and efficient of web page level extraction, with target of extracting the theme information, but not fine-grained data.
We get the number of its sibling nodes, set the serial number of its child node as 0, insert into the public XPath expression.
Firstly, define three variables, save the serial numbers of child nodes, the numbers of child nodes and step length values.
The initial value is the serial number of initial child node.
As show in table 1and table 2,the total number of data to be collected(#T) is 423.Since there are two formats about the information points of 2688 and joyo amazon shops, when the provided samples number(#N) is 2,the number of actual extracted information points(#E) is 366,in which 360 information points is correct(#C) ,and the average value of F is 75.23%,when the provided samples number is 3,the average recall value is 99.17%,the average precision value is 99.17% and the average value of F is 99.17%.
Online since: April 2012
Authors: Galina I. Zmievskaya, Anna L. Bondareva, V.V. Savchenko, Tatiana V. Levchenko
(5) Here Uij(r) corresponds to an indirect interaction of blisters with each other; Usurf(r) corresponds to the blister interaction with all surfaces of the layered structure (the interaction mechanism is the same), including the irradiated surface; Uph(r) corresponds to the interaction with lattice defects of the dislocation type and grain boundaries; and Upore(r) is the potential of the blister–pore interaction for porous materials.
If where k is an integer number, k³1 that , where Vblister is the blister volume, Vvac is the vacancy volume.
Results of numerical simulation of blister-pores evolution with number of interacting particles 300, number of trajectories 107, time step for size change is 10-9s, time step for migration is 10-8s, number of time step for size change is 105, number of time step for migration is 104.
The number of trajectories is 107, time step for size change is 10-9s, time step for migration is 10-8s, number of time step for size change is 105, number of time step for migration is 104.
Results of numerical simulation of cone blister-pores evolution with number of interacting particles 300, number of trajectories 107, time step for size change is 10-9s, time step for migration is 10-8s, number of time step for size change is 105, number of time step for migration is 104.
Online since: January 2013
Authors: Hong Chao Kou, Ruo Lin Li, Xiang Hong Liu, Ting Li Lu, Q. Li, Lian Zhou, Guang Sheng Xu
The cell numbers were equal in each well (5 × 104/ml) at the beginning of each experiment.
However, upon incubation of the cells with some of the discs their numbers sig-nificantly changed in time and this is reflected by changes in numbers of adhering cells as macrophages must adhere in order to survive in in vitro conditions.
As can be seen from the photos that hydroxyapatite distribution is more dispersive, where some of the original surface slices grain is visible, and some distribution is obvious on the porous titanium surface without precalcified.
The number of cells on all specimen are less than that of standard sample (Control) cell number, no matter the surface modified or not.
Cell numbers cultivated 7 days are obviously higher than that of the cell number cultivated 3 days.
Showing 21771 to 21780 of 28485 items