Silicon Carbide Power Diodes as Radiation Detectors

Article Preview

Abstract:

We have tested the radiation detection performance of Silicon Carbide (SiC) PIN diodes originally developed as high power diodes. These devices consist of 100 micron thick SiC grown epitaxially on SiC substrates. The size and thickness of the devices make them appropriate for a number of radiation detection applications. We tested 0.25 cm2 and 0.5 cm2 devices and obtained X-ray spectra under illumination with an Am-241 radioactive source. The spectra showed an energy resolution that was consistent with the resolution expected for the large capacitance of the device. Smaller devices with a diameter of 1 mm were also tested and produced spectra with a room temperature energy resolution of ~550 eV, which is consistent with the electronics limit for the capacitance of the small device. We measured the absolute charge generated by X-rays per KeV in SiC by comparing the charge generation with similar silicon devices and determined the energy required per electron hole pair in SiC to be 8.4 eV. We also performed radiation damage tests on these devices and found no significant loss in charge collection up to a photon dose of 100 MRad. Applications for these devices can be found in the fields of particle physics, nuclear physics, nuclear medicine, X-ray fluorescence, X-ray astronomy and X-ray navigation.

You might also be interested in these eBooks

Info:

Periodical:

Materials Science Forum (Volumes 527-529)

Pages:

1465-1468

Citation:

Online since:

October 2006

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2006 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] A.R. Dullo, et al.: IEEE Trans. Nucl. Sci. NS-46 (1999), p.275.

Google Scholar

[2] RD50 Status Report 2002/2003, CERN-LHCC-2003-058, (2003).

Google Scholar

[3] G. Bertuccio and R. Casiraghi: Study of Silicon Carbide for X-Ray Detection and Spectroscopy, IEEE Trans. Nucl. Sci. Vol. 50 (2003), p.175.

DOI: 10.1109/tns.2003.807855

Google Scholar

[4] G. De Geronimo et al.: Development of a High-Rate High-Resolution Detector for EXAFS Experiments, IEEE Trans. Nucl. Sci. Vol. 53 (2003), p.885.

DOI: 10.1109/tns.2003.814540

Google Scholar

[5] G. P. Golubev, V. S. Vavilov, and V. D. Egorov: Energy of ionization by electrons in germanium and silicon carbide crystals, Sov. Phys. Solid State Vol. 7, no. 12 (June 1966), pp.3000-3001.

Google Scholar

[6] M. Rogalla, K. Runge, and A. Soldner-Rembold: Particle detectors based on semiinsulating silicon carbide, Nucl. Phys. B (Proc. Suppl. ) Vol. 78 (1999), p.516.

DOI: 10.1016/s0920-5632(99)00596-4

Google Scholar