Predicting Hoop Tendon Behaviour in Pre-Stressed Concrete Containment Vessel

Abstract:

Article Preview

This paper is based on the experimental and numerical analysis work carried out as part of an international round robin aimed to predict the limit load of the ¼ scale Pre-stressed Concrete Containment Vessel (PCCV) which was tested at Sandia National Laboratories (SNL) in USA. The design pressure, Pd, for the PCCV was 0.39MPa. Pressurisation test was conducted causing global collapse of the PCCV structure, which occurred at the pressure of 1.423MPa (3.65 Pd). Displacements, loads and strains were monitored at 55 standard locations giving a unique opportunity to assess the accuracy and reliability in predicting failure modes and limit loads of PCCV structures. To simulate the inelastic response of the structure with extensive concrete cracking requires specialist numerical models and detailed geometric representation of the main structural features. One of the most important structural features was the prestressed hoop tendon system. The paper presents a brief explanation of the test, the instrumentation used to monitor the tendon behaviour and describes the analytical models employed to predict the tendon behaviour.

Info:

Periodical:

Edited by:

M. Lucas

Pages:

251-260

DOI:

10.4028/www.scientific.net/AMM.1-2.251

Citation:

N. K. Prinja et al., "Predicting Hoop Tendon Behaviour in Pre-Stressed Concrete Containment Vessel", Applied Mechanics and Materials, Vols. 1-2, pp. 251-260, 2004

Online since:

September 2004

Export:

Price:

$35.00

In order to see related information, you need to Login.

In order to see related information, you need to Login.