Flexural Tests on the H-Section Simple Beams with Local Buckling
Abstract:
This paper describes a series of flexural tests conducted on the H-section beams fabricated from SM490 plate of thickness 0.6mm with nominal yield stress 315 MPa. Flexural members with large width-to-thickness ratios in the flanges or the web may undergo local buckling before lateral-torsional buckling. The local buckling has a negative effect on the moment capacity based on the lateral-torsional buckling. Simple bending moment capacity formulas for flexural members were calibrated to the test results to account for interaction between local buckling and lateral-torsional buckling. The ultimate flexural strengths predicted by the proposed formulas for direct strength method were compared with the AISC (2005) and Eurocode3 (2003). The comparison showed that the moment formulas proposed can predict conservatively the bending moment capacity of H-section flexural members with local buckling.
Info:
Periodical:
Pages:
1677-1680
Citation:
Online since:
September 2011
Price:
Сopyright:
© 2012 Trans Tech Publications Ltd. All Rights Reserved
Share:
Citation: