Effect of Plant in Two Atrium Building Comfort: Report on Two Field-Monitored Case Studies

Article Preview

Abstract:

This paper present the field-measured thermal performance of two atrium building in a clinic center located in Kerman, where winter is cold and dry. The case studies are an enclosed atrium space. The atriums have open corridors at each storey connecting them to adjacent space. The site measurement and monitoring work were carried out for one day covering clear day in November 2010. The weather conditions during the day measuring period were stable and heating system was off. This study will investigated about different temperature of atrium levels with plant and without plant. This study has shown that in cold and clear winter day, when average of external relative humidity in this day was around 9%,in the atrium relative humidity changed between 10%- 22% and total temperature in atrium level were changed between 18'C-28'C. whilst in the atrium without plant this range were between 3%-23% and 15'C-35'C respectively.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1958-1962

Citation:

Online since:

October 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] A.H. Abdullah: study on indoor thermal environment in an atrium in tropical climates , Submitted to Journal of Building and Environment Vol. 44 (2009), PP. 431– 436.

DOI: 10.1016/j.buildenv.2008.02.011

Google Scholar

[2] MR. Atif: Atrium buildings: amenities, energy costs and environment, Submitted to Journal of Construction Canada Vol. 36 (1993), PP. 43–47.

Google Scholar

[3] MR. Atif, D.E. Claridge, L.O. Boyer, and L.O. Degelman: Atrium buildings: thermal performance and climatic factors( http: /www. nrc-cnrc. gc. ca/irc).

Google Scholar

[4] N. Baker, M. R Atif, and L. L Boyer: Validation of the algorithms developed for preliminary prediction of daylight distribution in a top lighted atrium (The Fifth Symposium on Improving Building Systems in Hot and Humid Climates, Houston, TX 1988).

Google Scholar

[5] j. Du: Computational simulations for predicting vertical daylight levels in atrium buildings (Eleventh International IBPSA Conference Glasgow, ScotlandJuly 2009).

Google Scholar

[6] B. Givoni: Comfort, climate analysis and building design guidelines, Submitted to Journal of Energy and Buildings Vol. 18 (1992), p.11–23.

DOI: 10.1016/0378-7788(92)90047-k

Google Scholar

[7] A. Laouadi, M.R. Atif: Comparison Between Computed And Field Measured Thermal Parameters In An Atrium Building, Submitted to Journal of Building And Environment Vol. 34 (1999), pp.129-138.

DOI: 10.1016/s0360-1323(98)00007-9

Google Scholar

[8] A. Laouadi , M.R. Atif and A. Galasiu: Methodology towards developing skylight design tools for thermal and energy performance of atriums in cold climates. Submitted to Journal of Building and Environment Vol. 38, (2003) p.117 – 127.

DOI: 10.1016/s0360-1323(02)00009-4

Google Scholar

[9] P. Littrefair: Daylight prediction in atrium buildings, Submitted to Journal of Solar Energy Vol. 73 (2002), p.105–109.

DOI: 10.1016/s0038-092x(02)00038-5

Google Scholar

[10] O. Göçer, A. Tavil, and E. Özkan: Thermal performance simulation of an atrium building (ESim 2006 Building Performance Simulation Conference Faculty of Architecture, Landscape, and Design, University of Toronto, Canada 2006).

Google Scholar

[11] j. Tencar: Influence of Plants on Microclimate in Atria – work in progress (http: /mat. fsv. cvut. cz/komisevstez/13/prispevky/tencar. pdf).

Google Scholar