Causes Analysis and Counter Measures to Bad Riveting of the Top Cylinder Head of the Compressor

Abstract:

Article Preview

In the trial-produce process of the CSA804 compressor, it was found that the appearance was not very good after riveting the top cylinder head. Most have the flanging phenomenon and the leakage detecting FPY cannot reach the mass production requirements. For this problem, through analyzing the related sizes of the top cylinder head, understanding the principle of the riveter, and considering the viveted method, the reasons of the bad reveting of the top cylinder head can be analyzed. Accordingly, the corresponding improvement measures can be taken to make the leakage detecting disqualification be lowed to the normal levels.