Effect of Image Motion and Vibration on Image Quality of TDICCD Camera

Article Preview

Abstract:

Image motion and vibration are significant factors influencing image quality of satellite-based TDI camera. In order to learn their effect on TDICCD, motion degradation models at two directions were established. Based on the models, Line spread functions (LSF) for image motion of different types and strict expressions of MTF for abnormal linear image motion were deduced. Modulation transfer function (MTF) for sinusoidal image vibration was calculated through numerical integration. Geometric distortion was evaluated by linear part of phase transfer function (PTF). The results indicate that abnormal linear motion and high frequency vibration cause space-invariant image blur while low frequency vibration brings space-variant image blur and geometric distortion.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

584-588

Citation:

Online since:

October 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] H. S. Wong, Y. L. Yao, E. S. Schlig. TDI charge coupled devices: Design and applications[J]. IBM J. RES. DEVELOP, 1992, 36(1): 83-106.

DOI: 10.1147/rd.361.0083

Google Scholar

[2] O. Hadar, I. Dror, N. S. Kopeika. Image resolution limits resulting from mechanical vibrations. Part IV: real-time numerical calculation of optical transfer functions and experimental verification[J]. Optical Engineering, 1994, 33(2): 566-578.

DOI: 10.1117/12.153186

Google Scholar

[3] A. Stern, N. S. Kopeika. Analytical method to calculate optical transfer functions for image motion and vibrations using moments[J]. Opt. Soc. Am. A, 1997, 14(2): 388-396.

DOI: 10.1364/josaa.14.000388

Google Scholar

[4] Qi Huaichuan, Huang Qiaolin, Hu Yongli. The Study about the means of simulation for the motion blurred of space optical remote sensing[J]. Spacecraft Recover & Remote Sensing, 2010, 31(2): 51-56. (in Chinese).

Google Scholar

[5] Jiagu Wu, Zhenzhen Zheng, Huajun Feng et al. Restoration of TDI camera images with motion distortion and blur[J]. Optics & Laser Technology, 2010, 42(8): 1198-1203.

DOI: 10.1016/j.optlastec.2010.03.010

Google Scholar

[6] S. L. Smith, J. Mooney, T. A. Tantalo, R. D. Fiete. Understanding image quality losses due to smear in high-resolution remote sensing imaging systems[J]. Opt. Eng, 1999, 38(5): 821-826.

DOI: 10.1117/1.602054

Google Scholar

[7] R. E. Jodoin. Linear phase shift removal in OTF measurements[J]. Opt. Soc. Am. A, 1986, 25(8): 1261-1262.

DOI: 10.1364/ao.25.001261

Google Scholar