Analysis the Reason of Head and Tail Pully Driving and Bidirectional Motor Negative Phase Sequence over Current Protection Malfunction

Abstract:

Article Preview

Analysis the wiring of head and tail pully driving & bidirectional 6KV motor,and found the reason of negative phase sequence over current protection malfunction did occur when the motor ran in the reverse direction , then compared the solution methods to make sure which one is better. At last use the method that change the sampling program to make the motor negative phase sequence over current protection wil in effect.

Info:

Periodical:

Edited by:

Han Zhao

Pages:

2800-2804

DOI:

10.4028/www.scientific.net/AMM.130-134.2800

Citation:

R. C. Yang et al., "Analysis the Reason of Head and Tail Pully Driving and Bidirectional Motor Negative Phase Sequence over Current Protection Malfunction", Applied Mechanics and Materials, Vols. 130-134, pp. 2800-2804, 2012

Online since:

October 2011