Structural Response Analysis of Beijing Yin-Tai Center Building under Varying Ground Motions

Article Preview

Abstract:

Deeply studying vibration and seismic response characteristics of Beijing Yin-tai Center provided information reflecting its anti-seismic performance based on which seismic response observation array was to be deployed. Time-historic analytical methods on the basis of modal analysis were applied to carry out structural seismic response. Two load cases were mentioned including the responses under minor earthquakes and moderate earthquakes. El-Centro wave, Northridge wave and synthetized time-histories were adopted with contrast analysis under Beijing Hotel time-history recorded in Tangshan Earthquake. Peak inter-story shift ratios and peak accelerations are obtained and analyzed. The inter-story shift ratio determines elastic state of structure under minor earthquakes and elastic-plastic state under moderate earthquakes. Predominant inter-story displacement and acceleration response provides the floors with more remarkable seismic response, which are vulnerable floors for monitoring in earthquakes.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

217-222

Citation:

Online since:

November 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Ye LP, Qu Z, and Lu XZ, etc: The ability of anti-collapse of building structures -lessons learned from earthquake damages of structures in the Wenchuan Earthquake. Journal of building structures, Vol. 29(2008), P. 42~50 (in Chinese).

Google Scholar

[2] Liu HX: Seismic hazards in Tangshan earthquake. Seismological Press, Beijing, China (1985) (in Chinese).

Google Scholar

[3] Wang YY, Pi SY. Characteristics and earthquake disaster experiences obtained from Taiwan major earthquake on Sept. 21 in. Earthquake Resistant Engineering, (2000), P. 42~46(in Chinese).

Google Scholar

[4] Cui JW, Zhao YQ, FU ZX, etc. Earthquake insulation and seismic response observation for high- rise building. Journal of seismological research, Vol. 25 (2002), P. 173~185 (in Chinese).

Google Scholar

[5] Zhou ZH, Li T, Dai ZY, etc. Observation system of responses of building to earthquakes. Progress in Geophysics. Vol. 19(2000), P. 868~872 (in Chinese).

Google Scholar

[6] Wang F, Hu P. Research on structural seismic response observation system in Chinese Mainland. Recent Developments in World Seismology, (2006), P. 8~13(in Chinese).

Google Scholar

[7] Yue ZR, Zhou HY, Chen YP. Three-dimensional seismic response analysis of a Garden mansion. Earthquake Resistant Engineering, (1999), P. 3~7(in Chinese).

Google Scholar

[8] Song JX, Jia ZY, Hai YL. Seismic response analysis of the main workshop in a thermoelectric plant. Journal of Zhengzhou University of Technology, Vol. 19 (1998) P. 39~ 46(in Chinese).

Google Scholar

[9] Zhu JQ. Analytical theory for earthquake-resistance of structures. Seismological Press, Beijing China (2002) (in Chinese).

Google Scholar

[10] Jia XJ, He RQ, Zhang YG, etc. Analysis of different damping ratio influence on steel structures. China Mine Engineering, Vol. 35(2006) P. 41~44(in Chinese).

Google Scholar

[11] Yang BP, Sun MB, Yang XM. Seismic Motion Input for High-Rise Buildings. Building Science, Vol. 15(1999) P. 6~13(in Chinese).

Google Scholar

[12] Zhang XP. Structural nonlinear analysis of reinforced concrete anti-seismic structures. Science Press,Beijing China (2003) (in Chinese).

Google Scholar