Numerical Study on Structural Improvement of the Grill Fixed at the Outlet of the Air Conditioner Outdoor Unit

Abstract:

Article Preview

This paper presents the techniques to numerically simulate the inner flow field of the air conditioner outdoor unit with Fluent. The results are verified experimentally and proved to be mesh-independent. The possibility of improvement to increase the flow rate by modifying the grill’s structural parameters is shown through analyzing the numerical results. The gill’s structure is improved using the flow field information got from numerical simulation and the improvement helps to increase flow rate by 4.1% and reduces the turbulent intensity near the grill significantly.

Info:

Periodical:

Edited by:

Hun Guo, Taiyong Wang, Zeyu Weng, Weidong Jin, Shaoze Yan, Xuda Qin, Guofeng Wang, Qingjian Liu and Zijing Wang

Pages:

386-391

DOI:

10.4028/www.scientific.net/AMM.141.386

Citation:

Y. Liu and C.J. Wu, "Numerical Study on Structural Improvement of the Grill Fixed at the Outlet of the Air Conditioner Outdoor Unit", Applied Mechanics and Materials, Vol. 141, pp. 386-391, 2012

Online since:

November 2011