Research on Fluorescence Imaging Detecting System of Intracellular Calcium

Article Preview

Abstract:

A new effective imaging detecting system has been used to determinate of intracellular calcium. The fluorescence Image acquisition and analysis was realized with fluorescence imaging detecting system. A designed microfluidic chip has been built. Cell fostering, staining and other operations can be implemented on it. Based on it, a new detecting means was developed for fluorometric measurement. The concentration of intracellular calcium ion can been calculated by using the fluorescence ratio method. A series of experiments were performed by using the detecting system. The experimental results show the ratio of fluorescence intensity was positively correlated to the raising temperature and enhancing shear stress.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

38-41

Citation:

Online since:

December 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Kiedrowski L, Brooker G, Coota E, etal. Glutamate impairs neuronal calcium extraction while reducing sodium gradient, Neuron, 1999, 12, 295-300.

DOI: 10.1016/0896-6273(94)90272-0

Google Scholar

[2] Geppert M, Goda Y, Hammer RE, et al. Synaptotagmin I: a major Ca2+ sensor for transmitter release at a central synapse, Cell, 1994(79): 717-727.

DOI: 10.1016/0092-8674(94)90556-8

Google Scholar

[3] A. Takahashi, P. Camacho, J.D. Lechleiter and B. Herman, Measurement of Intracellular Calcium, Physiological Rev 1999(79): 1089.

DOI: 10.1152/physrev.1999.79.4.1089

Google Scholar

[4] Yoshihisa K, Kazuho O, Monitoring of intracellular [Ca2+]i elevation in single neural cell using a fluorescence microscope/video-camera system, Japan J Pharmacol, 1996, 41: 345~351.

DOI: 10.1254/jjp.41.345

Google Scholar

[5] Mznz A, Graber N, Widmer H M. Miniaturized total chemical analysis systems: a novel concept for chemical sensing[J]. Sens Actuators B, 1990, B1: 244.

DOI: 10.1016/0925-4005(90)80209-i

Google Scholar

[6] Li Hai, Shan Wang, Jin Xi, et al. Research on Transmembrane Behaviors of Y3+ by Fure-2 Fluorescence Probe, Chinese Journal of Inorganic Chemistry, 1999, 15(1): 83-88.

Google Scholar

[7] GRYNKIEWICZ, G., POENIE, M. & TSIEN, A new generation of Ca2+ indicators with greatly improved fluorescence properties, Biol. Chem., 1985, (260): 3440-3450.

DOI: 10.1016/s0021-9258(19)83641-4

Google Scholar

[8] Sui G D, Wang J Y, Lee C C, et al. Solution-phase surface modification in intact poly microfluidic channels. Analytical Chemistry, 2006, 78(15): 5543-5551.

DOI: 10.1021/ac060605z

Google Scholar

[9] Yin xuefeng, Shen hong, Fang zhaolun, A Simplified Microfabrication Technology for Production of Glass Microfluidic Chips, Chinese Journal Of Analytical Chemistry , 2003, 31(1).

Google Scholar

[10] Andersson H. Micro technologies and nanotechnologies for single-cell analysis, Current Opinion Biotechnology, 2004, 15(1): 44-49.

Google Scholar