Determination of Cl- and SO42- in Boric Acid

Article Preview

Abstract:

Microcontents of Cl- and SO42- in boric acid were determined by photoelectricity turbidimetry with acid as medium. The effects of stabilizer, acidity of solution, content of precipitant, heating time and temperature as well as measuring time on the turbidity of the solution were studied. After above experiment parameters were optimized, in the measurements to determine SO42- in boric acid, the stabilizer was glycerine-ethanol (1:4), the precipitant was acidic BaCl2. The solution was shaked and heated, as a result, the adding sequence of reagents had no effects on results. The detection limit was 0.10mg/L, relative standard deviation (RSD) was less than 3%, recovery rate was 98.85%~103.00%, and measuring time last over 40min. SO42- concentration in the range of 0.33 mg/L ~0.83mg/L showed a linear relationship with turbidity. In the determination of chlorine, the stabilizer was glycerine, measuring time held in 40min, detection limit was 0.03mg/L, RSD was less than 4%, and recovery rate was 102.2%~106.5%. Cl- concentration in the range of 0.10 mg/L ~0.25mg/L showed a linear relationship with turbidity. Photoelectricity turbidimetry improve the precision and accuracy of the measurements. The method of turbidimetry to determine Cl- and SO42- in boric acid is simple, reliable, innocuous and applicable in practice.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

507-512

Citation:

Online since:

January 2012

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] S. D. Kumar, K. Venkatesh and B. Maiti: Chromatographia, 59 (1992), pp.243-245.

Google Scholar

[2] S. Thangavel, K. Dash and S. M. Dhavile: submitted to Journal of Chromatography A, 1074(2005), pp.229-233.

Google Scholar

[3] J. Hedrick, A. Gutlerrez and D. Potter The analysis of trace elements in boric acid by ICP-MS. Application Note, HEWLETT PACKARD, Printed in USA, (1997).

Google Scholar

[4] P. Masson, F. Raemaeker and F. Bon: Accred Qual Assur, 10(2005), pp.439-443.

DOI: 10.1007/s00769-005-0026-3

Google Scholar

[5] L. F. Capitán-vallvey, E. A. Guerrero and C. B. Merelo: Anal Bioanal Chem, 380(2004), pp.53-569.

Google Scholar

[6] E. A. Pereira, A. Stevanato and A. A. Cardoso: Anal Bioanal Chem, 380(2004), pp.178-182.

Google Scholar

[7] E. J. Hakoila, J. J. Kankare and T. Skarp: Analytical chemistry, Vol. 44 (1972), p.1857.

Google Scholar

[8] S. M. B. Brienza, R. P. Sartini and N. J .A. Gomes: Analytica Chimica Acta, 308(1995), pp.269-274.

Google Scholar

[9] D. Y. Sarica, N. Ertas: Turk J Chem, 25(2001), pp.305-310.

Google Scholar

[10] N. Schmidt, M. Biesaga and A. Seubert: Microchim. Acta, 146(2004), pp.119-128.

Google Scholar

[11] J. M. Irache, C. Durrer and G. Ponchel: submitted to International Journal of Pharmaceutics, Vol. 90 ( 1993), pp.9-12.

Google Scholar

[12] China Standard Compile. Chemistry reagent-currency method about determination of sulfide. China Standard Press, (1988).

Google Scholar

[13] B. DU, S. R. Wang and Q. WEI: submitted to Chinese Journal of Analytical Chemistry, 23(1995), pp.662-664.

Google Scholar

[14] D. C. Rivard, L. A. Stricker and P. Neogi: submitted to Journal of Colloid and Interface Science, Vol. 149(1992), P. 521-527.

Google Scholar

[15] J. R. Song, S. J. LIU and X. P Zhu: submitted to Journal of East China Geological Institute, Vol. 2 (2002), pp.154-158.

Google Scholar

[16] A. E. Kaiser, A. L. Graham and L. A. Mondy: submitted to Journal of Non-Newtonian Fluid Mechanics, Vol. 2004, 16(2): 479-488.

DOI: 10.1016/j.jnnfm.2003.11.004

Google Scholar