Bearing Capacity Analysis on Slotted End Plate Connection Joints of Different Types

Article Preview

Abstract:

Four different types of full-scale slotted end plate (SEP) connection joints are tested to determine their failure modes and damage mechanisms under ultimate loading. Researches on mechanical behaviors of I-type, T-type, U-type and Groove SEP connection joints bearing compression are studied, which also analyze their force-displacement behaviors and developing processes of deformation and strain. The results show that the bearing capacities of I, grooved, T and U types SEP connections are increased gradually, which indicate the SEP’s type has great influence on the ultimate strength of joints. The instability of SEP is the main factor to cause the loss of bearing capacity of the connection, which is shown through the development of strain, that SEP enters into plastic stage and the other regions still are elastic.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

764-769

Citation:

Online since:

May 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Fu Juntao, Theoretical and experimental studies on ultimate strength of tubular joints applied for long-span steel towers[D]. Shanghai, Tongji University.2006.

Google Scholar

[2] Jin Xiaohua, Fu Juntao, et.al. Intensity analysis for cross-gusset connection steel tubular joints of transmission towers[J]. Steel Construction. 2006, 5(21):41-44.

Google Scholar

[3] Liu Hongjun. Behaviors and ultimate strength of steel tubular K-joints with gusset plate connection in UHV transmission tower[D]. Chongqing University, 2010.

Google Scholar

[4] Bai Qiang. The experimental investigation about ultimate strength of steel tubular tower's joint applied in extra-high voltage[D]. Chongqing University, 2009.

Google Scholar

[5] Wu Lian1gsheng, Sun Weimin, et.al. Nonlinear FEM analysis of bearing behaviour of steel tube connection with U-type flash board[J]. Journal of Nanjing university of technology (Natural Science edition). 2008, 30(1): 92-96.

Google Scholar

[6] Dai Gangping, Wang Shuhong, et.al. Nonlinear analysis on strength of full scale U-type connections with finite element method[J]. JiangSu Electrical engineering. 2009, 28(2): 44-47.

Google Scholar

[7] Tao Qingsong, Zhang Dachang, et.al. Experimental study of connection node load bearing performance of steel tubes connected by full scale U-shape inserting plate. Electric power construction[J]. 2009, 30(1): 32-34.

Google Scholar

[8] Tao Qingsong, Zhang Dachang, et.al. Experimental research on full-scale single slotted tube connection strength of long span transmission tower[J]. Special Structures. 2008, 25(5): 44-46.

Google Scholar

[9] Li Zhengliang, Liu Hongjun. Study of ultimate strength of gusset-plate steel tubular joint of transmission towers[J]. China civil engineering journal. 2011, 44: 52-58.

Google Scholar