System Design and Experiments Study on 120K the Segregation Linder Refrigerator with Pre-Cooling Cycle

Article Preview

Abstract:

Abstract. The separate condensing Linder refrigerator by using mixed-refrigerant with pre-cooling cycle in 120K temperature rang is proposed and the experimental device is established, then the corresponding experiments are conducted. The results show that the best ratio of ternary refrigerants(R23/R14/R740) is 0.63:0.28:0.09, the refrigerating temperature of the unimproved system without heat loads is 150 K, but the refrigerating temperature of the segregation Linder refrigerator system without heat loads is 120 K.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

2629-2633

Citation:

Online since:

May 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Chou F C, Cryogenics, 1995(35):311-316.

Google Scholar

[2] Xiong L Y, Cryogenics, 2004(44):801-807.

Google Scholar

[3] G. B.Chen, "The Latest Low Temperature Refrigeration Technology,"Eeijing: Mechanic industry Press. 2003.(in Chinese)

Google Scholar

[4] Zh. B. Dong, M. Q. Gong and J. F. Wu , Journal of Refrigeration, 2006(6): 9. (in Chinese)

Google Scholar

[5] Ch. J. Xiao and H. Sh. Liu , Cryogenics and Superconductivity, 2008(2): 28-30(in Chinese)

Google Scholar

[6] Levenduski R and Scarlotti R, Cryogenics, 1996(36):859-866.

DOI: 10.1016/0011-2275(96)00049-5

Google Scholar