Abstract:

This paper analysis the formation conditions of isolated power system, its influencing factors, revealing the operation mode, automatic safety device, generator protection regulation characteristics and these factors to stable operation of isolated power system. The dynamic models for isolated power system with generating unit of medium and small capacity are proposed in the paper to meet the need of the applicable ones to study their dynamic characteristics. The differences between isolated and the interconnected power system in the frequency characteristics are proposed and consider into low-frequency load shedding scheme and optimization methods that can meet both isolated and the interconnected power system frequency stability requirements. Not only more proper control strategy of units but their evaluation indexes are suggested to improve performance and achieve stability in islanded power system.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

328-332

Citation:

Online since:

July 2012

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] HUANG He; XU Guang-hu; YU Chang. Operation Experience of Isolated power system in CSG during Ice Disaster [J], China. 2009, 2(5):6-9.

Google Scholar

[2] US/Canada Power Outage Task Force. Causes of the August 14th blackout in the United States and Canada[J]. (2010).

Google Scholar

[3] IEEE Std. 1547TM, IEEE Standard for Interconnecting Distributed Resources With Electric Power Systems[S]. New York : IEEE Standards Coordinating Committee 21 on Fuel Cells, Photovoltaics, Dispersed Generation, and Energy Storage, (2009).

DOI: 10.1109/ieeestd.2008.4816078

Google Scholar

[4] ZHOU Zhi-ping; SUN Xin-liang; FU Chen-peng; LIU Ke,. Insular Power System Dynamic Characteristic Examination Research [J],China, 2001,32, 78-81.

Google Scholar

[5] Pilo F,Celli G,Mocci S. Improvemen to reliability in active networks with intentional islanding[J]. IEEE International Conference on Electric Utility Deregulation,Restructuring and Power Technologies,(2004).

DOI: 10.1109/drpt.2004.1338023

Google Scholar

[6] Pilo F,Celli G,Mocci S. Improvemen to reliability in active networks with intentional islanding[J]. IEEE International Conference on Electric Utility Deregulation,Restructuring and Power Technologies,(2004).

DOI: 10.1109/drpt.2004.1338023

Google Scholar

[7] P.M. Anderson. Power System Protection[M] (2009).

Google Scholar

[8] WANG Jun; WANG Xiao-ru; XIE Da-peng; CHEN Yi-xuan . Investigation of under frequency load shedding on an isolated system [J], 2010,38(3):29-52.

Google Scholar

[8] Li Aimin Cai Zexiang. Frequency Dynamics Analysis and Load Shedding Assessment Based on the Dynamic Simulation Trajectory of Interconnected Power System [J], 2009,24(9):171-177.

DOI: 10.1109/drpt.2008.4523613

Google Scholar